Possible values: 
0

 

- Smart Plug memorizes its state after a power failure. 

1 - 

Smart Plug does not memorize its state after a power failure. 

Connected device will be on after the power supply is reconnected.

 

2 - Smart Plug does not memorize its state after a power failure. 
Connected device will be off after the power supply is reconnected. 

 
Default value: 0 
Parameter size: 1 [byte] 

 

Parameter No. 03 Notification when Load status change 
Smart Plug will send notification to associated device (Group Lifeline) when the status of 
smart plug’s load is changed. 
 

Possible values: 

0 - The function is disabled. 
1 - Send Basic report. 
2 - Send Basic report only when Load status is not changed by Z-Wave Command. 
 
Default value: 1 
Parameter size: 1 [byte] 

 
 

Parameter No. 04 LED Load indicator mode selection 
 

Possible values: 

0 -The LED status follows the load change. 
1–when operating the load, The LED lights for 5 seconds and then turns off. 
Default value: 0 
Parameter size: 1 [byte] 
 
Parameter No. 16 

The value here represents minimum change in wattage (in terms of 

wattage) for a meter report (watt) to be sent 

When the change value of load power 

exceeds the setting value, smart plug will send meter 

report (watt) 

to associated device (Group Lifeline). 

 

Possible values: 
 -32768 to 32767

 (0 - 65535W) 

-

32768

 to -1

65535 to 

32768

 

1 to 

32767

: 1 to 

32767

 

 
0 - The function is disabled. 
 

Содержание HA-ZW-5PAB

Страница 1: ...ters regardless of vendor to increase reliability of the network Smart Plug is also a security Z Wave device and supports the Over The Air OTA feature for the product s firmware upgrade If you want yo...

Страница 2: ...ht is blue when the device is turned off the light changes to red 2 TECHNICAL SPECIFICATIONS Power supply 230V 10 50Hz Rated load current 10A Power consumption 1 5W Power output 2300W Operational temp...

Страница 3: ...frame 2 To remove the product from the Z Wave network a Insert the Smart Plug to power socket the LED will follow the status on or off of its load s power level b Set the Z Wave network main controlle...

Страница 4: ...V2 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2...

Страница 5: ...ommand such as short pressing 2 Sending Meter Report 3 Sending Device Reset Locally 5 2 Basic Command Basic CC maps to Switch Binary CC 5 3 Configuration Command Smart Plug offers a wide variety of ad...

Страница 6: ...0 The function is disabled 1 Send Basic report 2 Send Basic report only when Load status is not changed by Z Wave Command Default value 1 Parameter size 1 byte Parameter No 04 LED Load indicator mode...

Страница 7: ...the parameters 101 104 to default Possible values 85 Parameter size 1 byte Parameter No 101 Setting time for sending meter report watt The interval time of sending meter report watt to associated devi...

Страница 8: ...ssible values 5 2678400 5 2678400s Default value 3600 one hours Parameter size 4 byte Parameter No 254 Enable disable the configuration command Lock unlock all configuration parameters Possible values...

Отзывы: