Possible values:
0
- Smart Plug memorizes its state after a power failure.
1 -
Smart Plug does not memorize its state after a power failure.
Connected device will be on after the power supply is reconnected.
2 - Smart Plug does not memorize its state after a power failure.
Connected device will be off after the power supply is reconnected.
Default value: 0
Parameter size: 1 [byte]
Parameter No. 03 Notification when Load status change
Smart Plug will send notification to associated device (Group Lifeline) when the status of
smart plug’s load is changed.
Possible values:
0 - The function is disabled.
1 - Send Basic report.
2 - Send Basic report only when Load status is not changed by Z-Wave Command.
Default value: 1
Parameter size: 1 [byte]
Parameter No. 04 LED Load indicator mode selection
Possible values:
0 -The LED status follows the load change.
1–when operating the load, The LED lights for 5 seconds and then turns off.
Default value: 0
Parameter size: 1 [byte]
Parameter No. 16
The value here represents minimum change in wattage (in terms of
wattage) for a meter report (watt) to be sent
When the change value of load power
exceeds the setting value, smart plug will send meter
report (watt)
to associated device (Group Lifeline).
Possible values:
-32768 to 32767
(0 - 65535W)
-
32768
to -1
:
65535 to
32768
1 to
32767
: 1 to
32767
0 - The function is disabled.