background image

 

 

27

 / 

27

                                                                                                                         

 

 

Page up 

98 

 

Page down 

99 

 

Left Shift 

9A 

 

Left Ctrl 

9B 

 

Left Alt 

9C 

 

Left GUI 

9D 

 

Right Shift 

9E 

 

Right Ctrl 

9F 

 

Right Alt 

A0 

 

Right GUI 

A1 

 

Caps Lock 

A2 

 

 

Содержание 2.4G&AI-BS-WS40-V

Страница 1: ...1 27 Ai Hardware wireless barcode Scanner 2 4G AI BS WS40 V User Guide vision V1 5 ...

Страница 2: ... Language setting 5 4 3 To change the frequency of the wireless reception 6 4 4 Check the parameters 6 4 5 Working mode 6 4 7 Restore the factory settings 8 4 8 The command of firmware upgrade 10 4 9 Wireless connectivity detection Note this function only in a scanner connected to a receiver 10 4 10 The sender wired output 11 4 11 Wired connection USB USB VCP COM 11 4 13 Auto trigger 13 4 14 Start...

Страница 3: ...e scanning module transmission of data and processing NO Pin Type Instrctions 1 NC NG Reserved 2 VCC DC Power DC3 3V or DC5V According to the different modules 5 3 GND Ground GND 4 Rx I Serial input ports TTL level 5 Tx O Serial output ports TTL level 6 NC None Reserved 7 NC None Reserved 8 NC None Reserved 9 BPR O Buzzer hint Decode the output frequency of 3 k 150 ms output low level when not wor...

Страница 4: ...barcodes of the receiver need to be forward by the sender through wireless transmission W work on the sender and the receiver at the same time Type Consult the table of setting type Parameter The parameter is four characters in the range 0 9 3 4 Setting type 3 4 1 The table of setting type Type Description A Wireless pairing discharge pairing B Language settings C Check the Firmware info Change th...

Страница 5: ...seconds from the start of the receiver s power on the LED is flashing After 20s the LEDs are always on and cannot be paired This method is for a receiver without a button 2 Press buttons on the receiver the receiver will automatically enter the matching state during this period can be paired normally with button this way for receiving 3 2 4G stops flashing after pairing is successful and 433 stops...

Страница 6: ...ddress Instructions being check parameters command with the system parameters to receive terminators after each parameter is separated such as PKT protocol field WN W B1001 parameter 1 0 x0d parameter 2 0 x0d for the contents of the packet 4 5 Working mode Function Command Barcode Remark Real time mode WN T F0000 Scan and transmit data will automatically lost if upload failed Cache mode WN T F1000...

Страница 7: ...n enter setting state is not available when using the three operation setting commands if has entered the set state after the need to save first just can use 3 New 433 and 2 4G solutions product models are xxxx Storage data description Inventory mode Stores 30 Bytes of data for 49 000 Stores data with a length of 13 bytes for storing 104 500 Cache mode Stores data with a length of 30 Bytes and sto...

Страница 8: ...e to when used to connect wireless scanner cable can be set to no sleep no sleep mode is not recommended END Instructions The calculation method of sleep time 20 x n ms X for barcode after two decimal values 4 8 Restore the factory settings Function Command Barcode Remark SET Factory Reset WN W H0000 1 autoSetFactory 2 The current spectrum constant 3 Matching the address remains the sam 4 The wire...

Страница 9: ...at support serial output hardware Currently only the AI BS WS40 V receiver supports serial output 2 The new product optimizes the transmission method USB and RS232 serial port transmission will be automatically recognized no need to set serial port output END Note 1 The default is USB and RS232 serial output the system will automatically select USB or RS232 serial port output according to the hard...

Страница 10: ...onnected to the PC through the serial port and the system enters the upgrade mode after pressing the bottom button for 8 seconds Sender upgrade WN T K0000 1 Connect the PC through the USB cable then scan the upgrade barcode of the sender and then restart the device to detect the upgrade END 4 9 0x0A 过滤 开启会过滤掉字符串中间的 0x0A 换行符 字符串结尾 倒数第一和第二位 的 0x0A 不会被过滤 功能 指令 条码 备注 开启 0x0A 过滤 WN W F3301 开启后 字符串中间 的换...

Страница 11: ...the PCB via USB cable connection connection can be directly through the normal USB transmission do not use the wireless transmission Disable USB wired output WN T L0001 Shut down after insert USB cable only allows charging only through wireless data transmission END Note USB wired output is used only for the sender 4 11 Wired connection USB USB VCP COM Function Command Barcode Remark SET USB mode ...

Страница 12: ...e 1 The default for USB and RS232 serial Port output the system will automatically choose the USB or RS232 serial Port output according to the hardware without setting 2 USB and Virtual serial Port Virtual COM Port when switching need scan Settings to change but don t need to plug the receiver 4 12 Serial port setting Function Command Barcode Remark SET 3 10 1 Baud rate 2400 WN R D0000 4800 WN R D...

Страница 13: ...N T D0000 Enable infrared induction trigger Disable auto trigger WN T D0001 Disable infrared induction trigger END 4 14 Start symbol mode setting Function Command Barcode Remark SET No start symbol WN T I0000 Custom start symbol bar code WN T I0002 END The sample of start symbol mode setting To set a start symbol Ab9 in barcode 1234567 The barcode data will be Ab91234567 1 Scan SET barcode 2 Scan ...

Страница 14: ...an Custom end symbol barcode 3 Scan the following symbol B in turn 4 Scan Exit Save barcode 5 End symbol of factory reset 0x0D Enter 6 End symbol of commonly used symbols 0x0D Enter 0x0A 0x09 Tab 0x0D Enter 0x0A Line feed 0x09 Tab 4 17 Sender prompts sound selection When the wireless scanner is used normally there are two sounds The first sound is the sound of successful reading and the second sou...

Страница 15: ...ounds overlap Therefore the setting of the added sound switch can cope with the mode The group sounds are repeated and the sound is mixed 4 18 Receiving base sound Turn on the base boot sound Turn off the base boot sound 4 19 Transmitter wireless transmission tone Turn on the transmission sound Turn off the transmission sound Turn off all sound 5 Information instructions 5 1 Receiver instructions ...

Страница 16: ...igh mid low frequency Green light blinks once 10 Setting command state Long one beep and short one beep high low frequency Green light normally on 11 Effective command Long one beep and two short long high mid low frequency Green light blinks once 12 Non effective command Long one beep low frequency Green light blinks once Red light blink once Instructions of Inventory mode 13 Data uploaded succes...

Страница 17: ...ive the packet Green light blink once 433 receiver 1 Electricity boot Boot ringtone 2 power on within 30 seconds None Green light blink slowly 3 30 seconds later None Green light normally o n 4 Press the button to enter matching state None Green light blink slowly 6 2 4G Wireless sending and receiving data packet format 6 1 bk2425 Infinite packet format The statement field Size Description U8 pkt_...

Страница 18: ...write_addr 4Byte The initial address of can be written Inventory mode u32 read_addr 4Byte The initial address of can be read Inventory mode u32 mode2_write_addr 4Byte Initial address of can be written in the buffer Cache mode u32 mode2_read_addr 4Byte Initial address of can be read in the buffer Cache mode 8 433 wireless data packet The packet format The statement field Size Description U8 pkt_len...

Страница 19: ...he length of byte U8 pkt_check 1 byte 7 Address pairing indication marks 6 0 command packet 1 Data packet 5 Bar code transmission complete indication marks 0 Transmission complete 1 Transmission failure 4 Whether to showID 0 ID hide 1 ID show 3 0 Reserved 0 7 U16 src_addr 2byte source address U32 dst_addr 2byte destination address U16 cmd 2byte The command of ACK return Symbol table Control symbol...

Страница 20: ...20 27 I HTab 09 J LF 0A K VTab 0B L FF 0C M CR 0D N SO 0E O SI 0F P DLE 10 Q DC1 11 R DC2 12 S DC3 13 T DC4 14 U NAK 15 V SYN 16 W ETB 17 X CAN 18 Y EM 19 Z SUB 1A ESC 1B FS 1C GS 1D ...

Страница 21: ...21 27 RS 1E _ US 1F SPC 20 Symbol Hex 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 0 30 ...

Страница 22: ...22 27 1 31 2 32 3 33 4 34 5 35 6 36 7 37 8 38 9 39 3A 3B 3C 3D 3E 3F 40 A 41 B 42 C 43 D 44 E 45 ...

Страница 23: ...23 27 F 46 G 47 H 48 I 49 J 4A K 4B L 4C M 4D N 4E O 4F P 50 Q 51 R 52 S 53 T 54 U 55 V 56 W 57 X 58 Y 59 Z 5A ...

Страница 24: ...24 27 5B 5C 5D 5E _ 5F 60 a 61 b 62 c 63 d 64 e 65 f 66 g 67 h 68 i 69 j 6A k 6B l 6C m 6D n 6E o 6F ...

Страница 25: ...25 27 p 70 q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 Y 79 z 7A 7B 7C 7D 7E DEL 7F Function keys Hex F1 80 F2 81 F3 82 ...

Страница 26: ...7 F4 83 F5 84 F6 85 F7 86 F8 87 F9 88 F10 89 F11 8A F12 8B Backspace 8C Tab 8D Return ENTER 8E Enter Numeric Keypad 8F Esc 90 Arrow Down 91 Arrow up 92 Arrow right 93 Arrow left 94 Insert 95 Home 96 End 97 ...

Страница 27: ...27 27 Page up 98 Page down 99 Left Shift 9A Left Ctrl 9B Left Alt 9C Left GUI 9D Right Shift 9E Right Ctrl 9F Right Alt A0 Right GUI A1 Caps Lock A2 ...