Do not operate any electrical devices (e.g. wet vacuum cleaners) within the refrigerator compartment that
are not of the type recommended by the manufacturer. Devices with explosion protection markings (see
→
chapter 1.2) are permitted.
•
Steam or high-pressure cleaners may not be used for the basic cleaning (see
→
chapter 10.1.1).
•
Work on the electrical system and the cold system must only be performed by qualified staff (staff trained in
flammable refrigerants).
►
Opening the refrigerant circuit and suctioning of the refrigerant may only be performed in a well-
ventilated area outside of business hours of the market (without customer traffic) or outdoors.
►
Disconnect the unit before each maintenance/repair (see
→
chapter 9.2).
►
Secure the unit against restarting.
►
During repairs, a knowledgeable person who knows the local conditions must be available, as the
contact person, for the authorized AHT experts.
•
Dispose of units with flammable refrigerant and units with insulating foam (thermal insulation polyurethane
foam with pentane) appropriately. Inquire with the responsible authorities about the safety and statutory
disposal regulations applicable to you.
The product was designed to take into account the environmental and disposal friendliness of AHT units. The
refrigerant R-290 and the propellant pentane (for the insulating foam) do not have any ozone depletion potential
and do not contribute directly to the greenhouse effect.
Mechanical hazards
WARNING
•
Transport the unit with forklift trucks. Risk of injury to persons during collisions.
►
Observe the transport routes for forklift trucks.
►
Secure the cargo.
►
Forklift trucks must only be operated by trained persons.
•
Danger of tilting of the unit. Persons can be pinched (see
→
chapter 7).
►
Do not climb onto or into the unit.
•
Disposal of packaging material and films. Danger of suffocation.
►
Keep packaging material and foils away from children.
►
Do not let children play with them.
•
Missing and/or not fully functional safety devices. Danger of injury due to e.g. rotating parts.
►
Check the safety devices for completeness and functionality.
►
Guards and covers on the unit must not be removed.
CAUTION
•
Cutting injuries in the case of material breakage. Danger of falling.
►
Do not climb onto or into the unit.
•
Falling objects. Impact injury. Cutting injury in the case of glass breakage.
►
Do not place objects on the unit
•
Leakage of defrosted water. Slipping hazard.
►
Check for puddle formation in front of and below the unit.
►
Remove spilled defrosted water immediately.
•
Opening/Closing the glass lids. Hands (body parts) can be pinched.
►
During opening/closing do not grip the gaps.
►
When opening/closing pay attention to other people.