Step motor drive TSP10-BA 

    

         Page 5 of 13

 

TSP10

 

Adjustment 
 

The setting of motor current, the step resolution and the current reduction is done at TSP10-BA 
with two rotary switches (S1 = motor current, S2 = step resolution and current reduction). 
This type of parameter setting is less complex and easier to handle than the setting with dip 
switches and jumpers. 

Description of the jumpers and DIP switch positions on the step motor drive 6410: 

Pin 7 

 

 

 Pin 1 

 

 Position: open 

 

 

 

Pin 8 

 

 Pin 2 

 Position: close 

 

Motor current 

 

Overview of the settings for the motor current for the two

 

step motor drives 

 

6410 

TSP10-BA 

Motor current  

[A

rms

]

 

DIP6 

DIP7 

DIP8 

Switch S1 Position 

0,2 

--- 

--- 

--- 

0* 

0,4 

--- 

--- 

--- 

0,625 

open 

open 

open 

--- 

0,7 

--- 

--- 

--- 

1,0 

--- 

--- 

--- 

1,25 

open 

open 

close 

-- 

1,5 

--- 

--- 

--- 

1,875 

open 

close 

open 

--- 

2,0 

--- 

--- 

--- 

2,5 

open 

close 

close 

3,0 

---

 

---

 

---

 

3,125 

close 

open 

open 

--- 

3,5 

--- 

--- 

--- 

3,75 

close 

open 

close 

--- 

4,0 

--- 

--- 

--- 

4,375 

close 

close 

open 

--- 

4,5 

--- 

--- 

--- 

5,0 

close 

close 

close 

5,5 

---

 

---

 

---

 

6,0 

---

 

---

 

---

 

6,5 

---

 

---

 

---

 

7,0 

---

 

---

 

---

 

Switch S1 to position 0 = factory set-up

 

 

Содержание 6410

Страница 1: ... 6410 to TSP10 BA Technical Data Connection Configuration Adjustment values for motor current and step resolution Additional adjustment possibilities AHS Antriebstechnik GmbH Fichtenweg 17 64319 Pfungstadt Phone 49 6157 9866110 Fax 49 6157 9866112 ...

Страница 2: ...h heat sink 2 50 A 25 C 1 25 A 45 C 5 0 A 25 C 2 5 A 45 C 3 2 A 25 C 1 6 A 45 C 7 0 A 25 C 3 5 A 45 C Permissible heat sink tempreature forced cooling may be necessary Max 60 C Max 60 C Humidity 10 90 non condensing 10 90 non condensing Fault protection Short circuit phase to phase phase to zero conductor and over temperature Short circuit phase to phase phase to zero conductor and over temperatur...

Страница 3: ...supply can be connected to the motor connection Because of the B9 S25 serial adapter this applies also to the signal inputs outputs 6410 TSP10 BA Supply voltage Front side 3 pole Series terminals Bottom side FKCT 2 5 4 ST Motor connection Front side 5 pole Series terminals Bottom side FKCT 2 5 5 ST Signal inputs outputs Front side Sub D socket 9p Front side Sub D Socket 9p B9 S25 Seriell Adapter 5...

Страница 4: ...erial Adapter B9 Pin Signal Description Notes S25 Pin 1 Clock Clock pulse input 1 clock puls 1 step 8 2 Direction Input to control the direction of motor rotation 3 3 Enable TSP10 factory set up Signal without function 2 4 Activated Collector Transistor turned on at activated motor current 20 5 Not connected 7 6 Clock Clock pulse input 1 clock puls 1 step 6 7 Direction Input to control the directi...

Страница 5: ...han the setting with dip switches and jumpers Description of the jumpers and DIP switch positions on the step motor drive 6410 Pin 7 Pin 1 Position open Pin 8 Pin 2 Position close Motor current Overview of the settings for the motor current for the two step motor drives 6410 TSP10 BA Motor current Arms DIP6 DIP7 DIP8 Switch S1 Position 0 2 0 0 4 1 0 625 open open open 0 7 2 1 0 3 1 25 open open cl...

Страница 6: ...sitions 8 to F S2 Position 0 7 idle time 0 1 Second Idle Current Reduction to 50 S2 Position 8 F no current reduction 6410 TSP10 BA Revolutions per steps DIP1 DIP2 DIP3 J 3 4 Switch S2 Position with SSR without SSR 1 1 200 full step close close close set 1 9 1 2 400 Half step close close close open 2 A 1 2 400 Halfstep close close open set 2 A 1 2 5 500 3 B 1 4 800 close close open open 4 C 1 5 10...

Страница 7: ...is also transferred to switch position 8 The value ranges are as follows Step resolution 200 to 25600 steps per mech Revolution n x 50 Reduced motor current 0 to 100 of the nominal value Waiting time 1 to 3000 ms Enable signal At step motor control 6410 the enable signal input can be configured This can be used for example to activate the step motor control after switching on without establishing ...

Страница 8: ...d after 3 s TSP10 BA powered on but not enabled Green permanently on Motor current on motor stopped Orange blinking Motor current on motor is running Red blinking TSP10 BA turned off because of an error The blinking codes indicates the type of error 4 x blinking over temperature 7 x blinking over current Advanced connectivity Serial interface The serial interface RS 232 is required for the TopSuit...

Отзывы: