9
8
Table 2 — Centrotherm™
Appliance
adapter
Increaser
3-inch (7.6 cm) pipe
ISAA0303
N/A
4-inch (10.2 cm) pipe
ISAA0303
ISIA0304
DURAVENT POLYPROPYLENE PIPE
(Polypro single-wall gas vent system):
PolyPro
®
InnoFlue
®
Use the special appliance adaptor from DuraVent and
insert it in the rubber transition fitting on the blower
assembly outlet. Refer to
Table 3
and
Figure 9b
for
proper part number from DuraVent. On the four (4) inch
(10.2 cm) vent pipe, an increaser is necessary. Make
sure to use the Appliance Adapter clamp to connect
the PolyPro Appliance Adaptor to the Vent System
Adaptor and to tighten both hose clamps on the
Appliance Adapter Clamp to ensure the connection is
secure.
Table 3 — DuraVent™
Appliance
adapter
Increaser
Appliance
adapter
clamp
3-inch (7.6 cm) pipe
3PPS-AD
N/A
PPS-PAC
4-inch (10.2 cm) pipe 3PPS-AD 3PPS-X4
PPS-PAC
Through-the-Wall Venting Installation
Cut or drill a hole through the exterior wall, slightly
larger than the diameter of the vent pipe selected.
Extend a section of pipe through the hole to the out-
side and attach the terminating elbow to the exterior
end of the pipe. Connect and secure all piping and
elbows from the power venter to the wall. When the
installation is completed, the vent terminal must be at
two (2) inches (5.1 cm) from the exterior surface of the
wall (
see Figure 8
).
Figure 11
1) Vent pipe
2) Power vent assembly
3) Union
4) Cold water
manual shut-off valve
5) Cold water inlet
6) Expansion tank
7) Temperature
& pressure-relief valve
8) Overflow tube
9) Drain valve
10) Drain pan
11) Free-flowing floor drain
12) Inner access doors
13) Outer access door
14) Flammable Vapor
Sensor
15) Cap
16) Drip leg (sediment trap)
17) Gas supply
manual shut-off valve
18) Union
19) Gas control valve
20) Rating plate
21) Side tappings
22) Dip Tube
23) Hot water outlet
24) Union
25) Ignitor
26) Flame sensor
27) Burner orifice
28) Burner
Minimum Slope
1/4”/foot (21 mm/m)
INSTALLATION INSTRUCTIONS
2
5
6
3
4
7
8
21
9
10
11
12
15
16
17
19
20
23
24
22
28
26
25
27
1
18
14
13