  3. General 

3. GENERAL 

Congratulations on your purchase of this  AHLBORN  temperature measuring 

instrument for thermocouple sensors with a miniature thermal connector. You 

are strongly advised to properly familiarize yourself with the device's numerous 

possibilities and take the time to carefully read these operating instructions. 

This is absolutely necessary to avoid operating and measuring errors and to 

prevent damage to the device. To help you find the answers to your questions 

quickly and easily there is a comprehensive   index at the end these instruc-

tions. 

3.1 Warranty 

Each and every device, before leaving our factory, undergoes numerous quali-

ty tests. We provide a guarantee, lasting two years from delivery date, that your 

device will function trouble-free. Before you send your device to us, please ob-

serve the advisory notes in Chapter 11 Trouble-shooting. In the unlikely event 

that the device proves defective and you need to return it please wherever pos-

sible use the original packaging material for dispatch and enclose a clear and 

informative description of the fault and of the conditions in which it occurs. 
This guarantee will not apply in the following cases : 

The customer attempts any form of unauthorized tampering or alteration in-

side the device. 

The device is used in environments and conditions for which it is not suited. 

The device is used with an unsuitable power supply. 

The device is used for any purpose other than that for which it is intended. 

The device is damaged by electrostatic discharge or lightning. 

The user fails to observe and comply with the operating instructions. 

The manufacturer reserves the right to change the product's characteristics in 

the light of technical progress or to benefit from the introduction of new compo-

nents. 

3.2 Scope of delivery 

When you unpack the device check carefully for any signs of transport damage 

and ensure that delivery is complete. 

Measuring instrument THERM 2420 with 3 AA alkaline batteries 

These operating instructions 

In the event of transport damage please retain the packaging material and in-

form your supplier immediately. 

 4                     THERM 2420 

Содержание THERM 2420

Страница 1: ...____________________________ Operating instructions Temperature measuring instrument THERM 2420 V1 2 27 11 2007 www ahlborn com...

Страница 2: ...V REL Relative measuring 3 Operating keys ON OFF Switch the device on To switch device OFF press and hold down M M Meas point selection MAX MIN Max min value clear press and hold down MEM Measured va...

Страница 3: ...ation 6 7 CONNECTING THE TRANSDUCERS 6 8 DISPLAY AND KEYPAD 7 8 1 Display 7 8 2 Keypad 8 9 MEASURING OPERATIONS 9 9 1 Measured value 9 9 2 Measured value functions 9 9 3 Peak value memory 10 9 4 Measu...

Страница 4: ...r pos sible use the original packaging material for dispatch and enclose a clear and informative description of the fault and of the conditions in which it occurs This guarantee will not apply in the...

Страница 5: ...se substantial measuring errors You are advised therefore to wait until the device has adjusted to the ambient temperature before starting to use it Do not run sensor lines in the vicinity of high vol...

Страница 6: ...ry capacity drops to approx 10 percent the LOBAT arrow will appear in the display If the batteries are completely dis charged the device will switch off To replace old batteries first unscrew the batt...

Страница 7: ...omprises 41 2x 7 segment digits b for depicting various measuring functions a there are also 2 arrows e for depicting the operating status Function field Main field Display of measuring functions in t...

Страница 8: ...nction is locked This appears briefly Overshoots measuring range Maximum value flashes Undershoots measuring range Minimum value flashes 8 2 Keypad To operate the device a keypad with 7 keys is provid...

Страница 9: ...on field you will see the abbreviation for the thermocouple see Section 10 1 All special operating states possible for the measured value are explained in Section 8 1 9 2 Measured value functions By p...

Страница 10: ...20 any measured value can be saved To save the measured value press key MEM The currently saved value then ap pears in the function field preceded by the symbol M To jump back to the operating range d...

Страница 11: ...fy the value press keys M or M Entry is completed by again pressing key ON To terminate configuration at any time press key MEM 10 1 Measuring ranges The following measuring ranges can be set via menu...

Страница 12: ...eck the power supply charge the battery switch off and then on again If necessary re initialize see 6 2 Error Measuring functions or relative measuring cannot be started Remedy Check device configurat...

Страница 13: ...2kV IEC 61000 4 3 1995 A1 1998 A2 2000 3V m The following advisory notes must be observed when operating the device 1 If the standard sensor is extended 1 5 meters care must be taken to ensure that t...

Страница 14: ...ype J 200 0 950 0 C Cu CuNi Type U 200 0 600 0 C Cu CuNi Type T 200 0 400 0 C PtRh10 Pt Type S 0 0 1760 0 C Millivolt 10 000 55 000 mV Standard equipment LCD Measured value 5x 7 segment 15 mm 2x 16 se...

Страница 15: ...maximum value 9 3 10 Measured value 9 1 9 Measured value functions 9 2 9 Measured value memory 9 4 10 Measuring input 13 1 14 Measuring operations 9 9 Measuring ranges 10 1 11 Order no 13 2 14 Peak va...

Страница 16: ...13 Appendix 13 4 Your contact 16 THERM 2420...