  9. Measuring operations 

9.3 Peak value memory 

From the measured values acquired the high-

est   and   the   lowest   values   are   continuously 

recorded. To display these peak values press 

key 

   MAX   

 or 

   MIN   

 . As a check the display 

also includes the associated symbol. 

To display maximum value press key :

   MAX   

To display minimum value press key :

   MIN    

To delete maximum value press and hold down key :

   MAX   

    

To delete minimum value press and hold down key :

   MIN    

    

To jump back to the operating range display press key :

   M▲  

As soon as you clear the memory, the current measured value will appear (be-

cause measuring is continuous). 

9.4 Measured value memory 

On the THERM 2420 any measured value can 

be saved. To save the measured value press 

key 

   MEM   

 The currently  saved value then ap-

pears   in   the   function   field   preceded   by   the 
symbol ´

M

´.   To  jump  back   to  the  operating 

range display press key :

   M▲  

9.5 Relative measuring 

One very useful function is to zero the mea-

sured value at certain  locations or at  certain 

times as a reference value in order then to ob-

serve only the subsequent deviations. 
By default this function is also locked in the de-
vice configuration (display ´

LOC

´

) (see 10).

To zero-set the measured value 

press key :

   CLR   

To display relative measuring press arrow :

 

REL

To return to normal measured value : 

press and hold down   

 CLR 

Setting to zero automatically deletes the maximum and minimum val-

ues for this channel. The 

MAX

MIN

, and 

MEM

 functions are thus also 

available for relative measuring. 

 10                     THERM 2420 

Содержание THERM 2420

Страница 1: ...____________________________ Operating instructions Temperature measuring instrument THERM 2420 V1 2 27 11 2007 www ahlborn com...

Страница 2: ...V REL Relative measuring 3 Operating keys ON OFF Switch the device on To switch device OFF press and hold down M M Meas point selection MAX MIN Max min value clear press and hold down MEM Measured va...

Страница 3: ...ation 6 7 CONNECTING THE TRANSDUCERS 6 8 DISPLAY AND KEYPAD 7 8 1 Display 7 8 2 Keypad 8 9 MEASURING OPERATIONS 9 9 1 Measured value 9 9 2 Measured value functions 9 9 3 Peak value memory 10 9 4 Measu...

Страница 4: ...r pos sible use the original packaging material for dispatch and enclose a clear and informative description of the fault and of the conditions in which it occurs This guarantee will not apply in the...

Страница 5: ...se substantial measuring errors You are advised therefore to wait until the device has adjusted to the ambient temperature before starting to use it Do not run sensor lines in the vicinity of high vol...

Страница 6: ...ry capacity drops to approx 10 percent the LOBAT arrow will appear in the display If the batteries are completely dis charged the device will switch off To replace old batteries first unscrew the batt...

Страница 7: ...omprises 41 2x 7 segment digits b for depicting various measuring functions a there are also 2 arrows e for depicting the operating status Function field Main field Display of measuring functions in t...

Страница 8: ...nction is locked This appears briefly Overshoots measuring range Maximum value flashes Undershoots measuring range Minimum value flashes 8 2 Keypad To operate the device a keypad with 7 keys is provid...

Страница 9: ...on field you will see the abbreviation for the thermocouple see Section 10 1 All special operating states possible for the measured value are explained in Section 8 1 9 2 Measured value functions By p...

Страница 10: ...20 any measured value can be saved To save the measured value press key MEM The currently saved value then ap pears in the function field preceded by the symbol M To jump back to the operating range d...

Страница 11: ...fy the value press keys M or M Entry is completed by again pressing key ON To terminate configuration at any time press key MEM 10 1 Measuring ranges The following measuring ranges can be set via menu...

Страница 12: ...eck the power supply charge the battery switch off and then on again If necessary re initialize see 6 2 Error Measuring functions or relative measuring cannot be started Remedy Check device configurat...

Страница 13: ...2kV IEC 61000 4 3 1995 A1 1998 A2 2000 3V m The following advisory notes must be observed when operating the device 1 If the standard sensor is extended 1 5 meters care must be taken to ensure that t...

Страница 14: ...ype J 200 0 950 0 C Cu CuNi Type U 200 0 600 0 C Cu CuNi Type T 200 0 400 0 C PtRh10 Pt Type S 0 0 1760 0 C Millivolt 10 000 55 000 mV Standard equipment LCD Measured value 5x 7 segment 15 mm 2x 16 se...

Страница 15: ...maximum value 9 3 10 Measured value 9 1 9 Measured value functions 9 2 9 Measured value memory 9 4 10 Measuring input 13 1 14 Measuring operations 9 9 Measuring ranges 10 1 11 Order no 13 2 14 Peak va...

Страница 16: ...13 Appendix 13 4 Your contact 16 THERM 2420...

Отзывы: