Spent batteries are special waste and must be disposed of in an environmentally accep-
table way.  Take spent batteries back to your dealer or dispose of them in your local bat-
tery collection container !

Rechargeable battery operation:

Instead of the standard batteries you can use rechargeable battery packs.
Rechargeable batteries are of lower capacity, 110 mAh, and provide an opera-
ting time of only 25 hours.  If sensors or modules also requiring power are con-
nected, the operating time will be accordingly shorter.  From our range of ac-
cessories we recommend the 9-volt rechargeable battery with a charger inte-
grated in the connector, ZB 2000 LS. 

Tips on the correct handling of rechargeable batteries:

The rechargeable batteries supplied are not usually charged when delivered. 

If NiCd cells are only partly discharged, normal recharging will not restore them

to full capacity. 

For this reason use the device until the batteries are nearly totally discharged 

and then recharge them completely. 

This will significantly prolong the life of your rechargeable batteries. 

Even fully charged batteries discharge in storage without being used.

3.2  External voltage supply

On the right side of the device there is a socket (4) for connecting an external
power supply.  In our range of accessories we offer a mains adapter ZB
2290-NA (12 V / 200 mA).  Or, alternatively, you can use some other DC po-
wer source (7 to 13 V).  The power source is connected by means of a low-vol-
tage connector (NES1 as per DIN 42323), center pin to minus.  
If, however, the power supply has to be electrically isolated from the transdu-
cers or if a larger input voltage range (10 to 36 V DC) is required, electrically
isolated supply cable ZB 2290-UK must be used.  It will then be possible to
operate the measuring instrument using a 12- or 24-volt on-board supply sy-
stem.

If a battery is connected, this will, in the event of a voltage drop
below 9 volts, take over as power supply.

3.3 Switching ON and OFF

The slide switch (1) on the left side of the device has two switch positions : 

up :  

ON  

i.e. to switch ON 

down :  

OFF  

i.e. to switch OFF

Certain device parameters, e.g. print cycle (00:00), analog reference channel
(measuring channel), temperature compensation (25 °C), air pressure (1013
mbar), and hysteresis (10 digits) can be permanently programmed via the in-
terface.  To reset these parameters to their default values (shown in brackets),
keep the 

CLEAR

 key pressed down when switching ON.

    ALMEMO

 2390-3

11   

 Power supply   

Содержание ALMEMO 2390-3

Страница 1: ...Operating instructions Universal measuring instrument ALMEMO 2390 3 V2 0 11 12 2003 ALMEMO 2390 3 1...

Страница 2: ...nal voltage supply 11 3 3 Switching ON and OFF 11 4 CONNECTING THE SENSORS 12 4 1 Sensors 12 4 2 Measuring inputs and additional channels 13 5 DISPLAY 14 6 SENSOR PROGRAMMING 15 6 1 Measuring range 15...

Страница 3: ...8 TROUBLE SHOOTING 21 9 ELECTROMAGNETIC COMPATIBILITY 22 APPENDICES 23 Technical data 23 Product overview 23 Your contact partners 24 ALMEMO 2390 3 3 Table of contents...

Страница 4: ...Interface modules RS232 optic fiber Centronics Manual Section 5 2 The entire ALMEMO networking system Manual Section 5 3 All functions and their operation via the interface Manual Section 6 Complete...

Страница 5: ...ALMEMO measuring instrument and to interchange these without the need for any extra settings Function channels Maximum minimum and average values and differences at certain measuring points can be pr...

Страница 6: ...easured value for the selected measuring point is shown continuously with auto zero and as and when necessary with measured value correction With most sensors sensor breakage is detected automatically...

Страница 7: ...ctor To avoid excessive data flow the data output of certain channels can as and when necessary by means of the print cycle factor be restricted or altogether disabled It is also possible to summate p...

Страница 8: ...minimum value HOLD Freeze measured value CLEAR Set measured value to zero Delete Max Min Hold 7 Battery compartment rear of dev 9 volt alkaline manganese battery 6F22 Space for reserve battery 5 LCD...

Страница 9: ...s M0 and M1 and then select measuring point M2 see 7 5 8 Evaluating a measuring operation call up maximum minimum values by pressing MAX or MIN key 6 delete maximum and or minimum values by pressing C...

Страница 10: ...n by the arrow as shown in the illustrations 2 Connect the battery using the clip Accidental re verse polarity is prevented by the shape of the connections 3 Use the second battery compartment to stor...

Страница 11: ...being used 3 2 External voltage supply On the right side of the device there is a socket 4 for connecting an external power supply In our range of accessories we offer a mains adapter ZB 2290 NA 12 V...

Страница 12: ...s Additional chan nels are available primarily for humidity sensors temperature humidity dew point mixture ratio or flow probes and chemical probes incorporating a tem perature sensor A single sensor...

Страница 13: ...However sensors combined within one connector and sensors with their own power supply are electrically intercon nected and must therefore be operated in isolation The volta ge applied to the measuring...

Страница 14: ...w 7 V symbol llights up BAT below 6 V L o b A t Checksum error during device calibration Non connected sensors deactivated measuring points Non permitted measuring range Sensor correction or scaling C...

Страница 15: ...iCroSil NiSil N ZA 9020 FSN 200 0 1300 0 C NiSi Fe CuNi L ZA 9000 FSL 200 0 900 0 C FECO Fe CuNi J ZA 9000 FSJ 200 0 1000 0 C IrCo Cu CuNi U ZA 9000 FSU 200 0 600 0 C CUCO Cu CuNi T ZA 9000 FST 200 0...

Страница 16: ...0 100 0 C H dt Partial vapor pressure cap FH A646 0 0 1050 0 mb H UP Enthalpy cap FH A646 0 0 400 0 kJ H En Humid temperature FN A846 30 00 125 00 C P Ht Relative humidity psychr FN A846 0 0 100 0 H...

Страница 17: ...nual Sec 5 1 1 7 1 Selecting the meas value and the measuring point After the device is switched on the MEASURE function is set and measuring point M0 for the first sensor is selected automatically i...

Страница 18: ...LUE function Select the maximum value MAX HOLD MIN MAX CORR M DIM The MIN VALUE function Select the minimum value MIN HOLD MIN MAX CORR M DIM Delete the max min values CLEAR Return to the MEASURE func...

Страница 19: ...or low the sensor will be adju sted and the correction values will be saved in the connector EE PROM see below Deleting the reference value The reference value for a channel can be deleted by pressing...

Страница 20: ...FY A640 O2 101 Example pH probe Zero point adjustment in a buffer solution of 7 00 pH Measured value HOLD MIN MAX CORR M DIM Zero point adjustment CLEAR HOLD MIN MAX CORR M DIM Gain adjustment in a bu...

Страница 21: ...r Fluctuating measured values or segment test or the system hangs in mid operation Remedy Check the cabling for inadmissible electrical connections disconnect the external power supply and the analog...

Страница 22: ...m IEC 61000 4 4 1995 A1 2000 2kV The following advisory notes must be observed when operating the device 1 If the standard sensor is extended 1 5 meters care must be taken to en sure that the measurin...

Страница 23: ...ZB 2290 NA 230 V AC to 12 V DC 200 mA electrically isolated Adapter cable el isol ZB 2290 UK 10 30 V DC to 12 V DC 250 mA Current consumption approx 4 5 mA without input and output modules Housing 18...

Страница 24: ...Your contact partners 24 ALMEMO 2390 3 Appendix...

Отзывы: