background image

Mini Merlin Installation, Operation & Maintenance                                                                                                                              

 

Rev: 03 05-22 

3  

Safety Information 

 

Before any installation, use or maintenance read this manual carefully. 

 

The information contained within this manual should be referenced for typical installation and operation only.  

 

For site specific requirements that may deviate from the information in this guide 

 contact your supplier.  

 

If this product is used in a manner not specified by the manufacturer, the safety provided by the product may be impaired. 

 

This product is designed for indoor operation only. 

 

Detectors and cables must be protected against mechanical damage. 

 

The internal fuse should be replaced only with the same type. Anti-surge fuse 3.15A 250Vac 5x20. 

 

The expected lifetime of gas sensor elements is 5 years upon initial power up. The device will display a message to indicate 
this time and should immediately be replaced. 

 

It is recommended that this product be commissioned upon installation and serviced annually. 

 

Do not apply lighter gas or other aerosols to the product 

 this will cause extreme damage. 

 

High concentrations of alcohol / ethanol found in many products may damage, deteriorate, or affect the gas sensing 
elements 

 Avoid exposure near your device. 

 

This equipment is designed to detect carbon monoxide and natural gas only - from any source of combustion.  

 

This product is not designed to detect smoke, fire or other gases and should NOT be used as such. 

 

This device provides early warning of the presence of LPG or carbon monoxide, usually before a healthy adult would 
experience symptoms. This early warning is possible provided your alarm is located, installed and maintained as described 
in this guide. 

 

This device requires a continual supply of electrical power 

 it will not work without power. 

 

This device should not be used to substitute proper installation, use and / or maintenance of fuel burning appliances 
including appropriate ventilation and exhaust systems. 

 

This device does not prevent LPG or carbon monoxide from occurring or accumulating. 

 

Actuation of your alarm indicates the presence of dangerous levels of LPG or CO. 

 

The device can respond to other gases other than its intended target such as Hydrogen (H2), Ethylene (C2H4) and Nitric 
Oxide (NO). In addition, the LPG sensor may react to iso-butane. 

 

Seek fresh air supply and contact your local gas emergency service should you suspect a gas leak. 

 

This device may not fully safeguard individuals with specific medical conditions.  

 

If in doubt, consult a doctor / physician. 

 

Your product should reach you in perfect condition, if you suspect it is damaged, contact your supplier

 

 

Warranty Statement

 

 

 

Warranty Coverage: The manufacturer warrants to the original consumer purchaser, that this product will be free of defects in 
material and workmanship for a period of two (2) years from date of purchase.  

The manufacturer’s liability hereunder is limited t

o replacement of the product with repaired product at the discretion of the 

manufacture. This warranty is void if the product has been damaged by accident, unreasonable use, neglect, tampering or other 
causes not arising from defects in material or workmanship. This warranty extends to the original consumer purchaser of the product 
only. Disclaimers: Any implied warranties arising out of this sale, including but not limited to the implied warranties of description, 
merchantability and intended operational purpose, are limited in duration to the above warranty period. In no event shall the 
manufacturer be liable for loss of use of this product or for any indirect, special, incidental or consequential damages, or costs, or 
expenses incurred by the consumer or any other user of this product, whether due to a breach of contract, negligence, strict liability 
in tort or otherwise. The manufacturer shall have no liability for any personal injury, property damage or any special, incidental, 
contingent or consequential damage of any kind resulting from gas leakage, fire or explosion. This warranty does not affect your 
statutory rights. Performance: During the above warranty period, your product will be replaced with a comparable product if the 
defective product is returned together with proof of purchase date. The replacement product will be in warranty for the remainder of 
the original warranty period or for six months 

 whichever is the greatest.  

 
 

Information on waste disposal for consumers of electrical & electronic equipment.

 

 

When this product reaches the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE).  
WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and 
recycling of the materials used. Please contact your supplier or local authority for details of recycling schemes in your area. 

 
At the end of their working life, electrochemical sensors should be disposed of in an environmentally safe manner.

 

Alternatively, they 

can be securely packaged and returned to AGS clearly marked for disposal. Electrochemical sensors should not be incinerated as 
this may cause the cell to emit toxic fumes

.  

 

Содержание Mini Merlin LPGCO v2-FL

Страница 1: ...O v2 FL Dual Gas Detector Installation Operation Maintenance Manual Please read this manual carefully and retain for future use For specific requirements that may deviate from the information in this...

Страница 2: ...uits 8 Wiring Adaptable Outputs 8 Wiring Pilot Water Heater Boiler Limit Breaker 9 Wiring Remote Shut Off 9 Auto Reset Buzzer Switches 9 Building Management System 10 Operation 10 Initial Power Up 10...

Страница 3: ...ic medical conditions If in doubt consult a doctor physician Your product should reach you in perfect condition if you suspect it is damaged contact your supplier Warranty Statement Warranty Coverage...

Страница 4: ...used for heating cooking and vehicles It is Obtained during the processing of crude oil or direct from the sea Colourless and odourless An odourising agent is added before distribution Half as heavy a...

Страница 5: ...ted in positions determined by those who have knowledge of gas dispersion the process plant system and equipment involved and in consultation with both safety and electrical engineering personnel Take...

Страница 6: ...electrical box Restrain the hazardous live wiring from accidental loosening to prevent wires from moving after installation and touching parts of opposite polarity or at low voltages Isolate the equi...

Страница 7: ...than connected Heat detectors use wires suitable for at least 167 F 75 C Wiring Gas Solenoid Valve When the installation includes a standing pilot ensure the internal auto reset dip switch is in the O...

Страница 8: ...iance Multiple appliance limit switches can be wired in series Wiring Adaptable Outputs The mini merlin can be used to effect external relays and contactors to disable multiple appliances when a fault...

Страница 9: ...mally closed and will alarm when energised open isolating the gas supply When using this input only the mains utility output shall de energize If you are using the CO or NG relay to shut down a boiler...

Страница 10: ...he touch sensor on the front cover for 3 seconds The detector enters a stabilisation phase for approximately one minute during this period the device is not operational If the detector has been config...

Страница 11: ...h button is pressed and held during normal operation the mini merlin will simulate an open circuit to ensure all configured systems outputs alarms indications and other external devices operate as int...

Страница 12: ...briefly exposing the unit to a known concentration of the target gas that usually exceeds the highest alarm point If the detector goes into alarm and all signals outputs activate then the system is w...

Страница 13: ...ylinder All cylinders will re seal upon removal of the regulator valve Deviating from this test process is deemed improper and may affect the functional safety of your device Exposure to chemicals smo...

Страница 14: ...ne LPG LEL Batch Cylinder No CO ppm Batch Cylinder No Propane LPG LEL Batch Cylinder No CO ppm Batch Cylinder No Propane LPG LEL Batch Cylinder No CO ppm Batch Cylinder No Propane LPG LEL Batch Cylind...

Страница 15: ...3 15A 250Vac Equipment Overvoltage Category II Pollution Degree 2 Relays Volt Free BMS relay output 0 5A switching current resistive load Environmental Ingress Protection Not Formally Evaluated Opera...

Страница 16: ...nded and is free from any unforeseen damage caused by transit installation Every effort is made to ensure the accuracy of this document however AGS can assume no responsibility for any errors or omiss...

Отзывы: