2.3  Safety Messages and Information on Remaining Risk

Protect the power supply cord from cutting edges. Have an authorized 
service shop replace damaged cables or lines immediately.

The machine has to be operated with a 230 V, 50/60 Hz power supply with 
safety fuse or breaker of 16 A maximum. If power is connected through 
a power line manifold, the power supply has to feature an earth-leakage 
circuit breaker.

Use only extension cables with the following conductor sections:

– max. length of cable 25 m (80 ft)  min. section 2.5 mm²
– max. length of cable 50 m (160 ft)  min. section 4.0 mm²

Caution

Parts Under Power

After  opening  the  machine  or  removing  the  cover,  parts  of  it 
are accessible that may be under power. The machine may be 
opened exclusively by an authorized service shop.

Caution

Facing Tool

Never  switch  the  facing  tool  on  when  it  is  not  in  its  regular 
working  position.  When  working  with  the  facing  tool,  do  not 
wear any jewellery and put on a hair snood or net as needed. 
Removing  the  shavings  from  the  work  area  while  the  facing 
tool is running, is prohibited. Make sure nobody is present in 
the danger zone.

Caution

Electrofusion Fitting

A welding process must never be repeated with the same fit-
ting, since this may cause parts under power to be accessible 
to the touch.

Caution

Checking the Product for Damage

Before  every  use  of  the  product,  check  safety  features  and 
possibly existing parts with minor damage for proper function. 
Make sure that the push-on connection terminals work properly, 
that contact is fully established, and that the contact surfaces 
are clean. All parts have to be installed correctly and properly 
conform to all conditions in order for the product to function as 
intended. Damaged safety features or functional parts should be 
properly repaired or replaced by an approved service shop.

Caution

Acceptable Work Conditions

The work zone has to be clean and has to have proper lighting. 
It is dangerous to operate in a humid environment or close to 
flammable liquids.
The electrofusion fitting manufacturer’s installation instructions 
and all applicable rules and regulations have to be respected in 
all cases. Acceptable work conditions have to be ensured (e.g., 
sufficient distance between the machine and other functional 
areas of the workshop).
Overhead work is prohibited, unless:-
• the machine is safely and securely fastened and positioned;
• access to a large area around the worksite is controlled/limited

(risk of falling objects); see also Sect. 2.5;

• a hardhat and safety goggles are worn (risk of falling objects and

small blades of shaving during component facing)

Important

Power Supply Only through Line with Protective Grounding 
Conductor

The system has to be operated exclusively with a power supply 
line equipped with a protective grounding conductor, as a power 

Содержание EF 110-B

Страница 1: ...lding System for Inside Beadless Welding EF 110 B Version October 2015 P O Box 1108 655 Andover St Lawrence MA 01843 Tel 800 343 3618 781 321 5409 Fax 800 787 6861 Website www asahi america com Email...

Страница 2: ...Welding Process 17 4 6 1 Facing the Component Ends before Welding 17 4 6 1 Connecting the Electrofusion Fitting 18 4 6 2 Reading the Fitting Code with a Scanning Pen or Handheld Scanner 18 4 6 4 Dire...

Страница 3: ...ely with a power supply line equipped with a protective grounding conductor as a power supply without this safety element may cause severe machine damage If the machine is operated through a power sup...

Страница 4: ...side beadless welding agru EF 110 B safely Every person who operates the system will have to conform to the instructions of this manual The machine has been developed and checked with respect to weldi...

Страница 5: ...ouch Caution Checking the Product for Damage Before every use of the product check safety features and possibly existing parts with minor damage for proper function Make sure that the push on connecti...

Страница 6: ...miliar with the applicable rules the guidelines for the prevention of accidents and the User s Manual The system may be operated only when observed Only persons who were properly trained by agru or an...

Страница 7: ...eaned and be locked against unwanted operation Important When the printer is moved or shipped the roll of labels in the printer has to be removed Inside view of the case for the reducer inserts R e m...

Страница 8: ...on fitting See Sect 3 3 for an overview of the welding process enabled by this system Only the welding parameters encoded in the fitting specific bar code can be used for a welding operation When join...

Страница 9: ...s the applicable welding time and controls the welding process automatically All welding and traceability data are entered with the keypad on the front panel or read from a code card using RFID radio...

Страница 10: ...x 240 mm 800 x 600 x 608 mm approx 6 kg approx 15 kg approx 4 kg approx 83 kg approx 42 kg 3 3 Welding Process Overview The welding system allows welding electrofusion fittings that feature a bar cod...

Страница 11: ...operation was a beadless welding the system keeps the balloon inflated to the end of the cooling stage and the user will have to release the air before the next jointing job 4 Operation Before putting...

Страница 12: ...unless the machine is safely and securely fastened and positioned access to a large area around the worksite is controlled limited risk of falling objects see also Sect 2 5 a hardhat and safety goggle...

Страница 13: ...lay 3 Depending on what data is entered either its repeated input is manda tory e g the welder ID code see Sect 4 1 or previously entered data can be changed and confirmed or confirmed without changes...

Страница 14: ...hat for two subsequent welding with identical welding fitting parameters the parameters of the preceding one are applied automatically to the following one see Sect 4 6 4 off that the parameters have...

Страница 15: ...N OFF on means that the weather has to be selected in a list before every welding off that this is not possible Installing Company ON OFF on means that the company that performs the installation work...

Страница 16: ...tarted when the welding process begins Info If a cooling time Tc is entered in the manual parameters this cooling time has to be waited before the cable between the system and the electrofusion fittin...

Страница 17: ...carriage of the mechinal structure Performing the same steps in reverse order place the fitting clamp the matches the diameter of the components to be jointed onto the middle carriage Insert the fitti...

Страница 18: ...ck selection screen opened from the Enter Fitting Code screen with the arrow key see Sect 4 3 In this screen the selection cursor can be moved using the and cursor keys the selection is made with the...

Страница 19: ...far as possible Finally insert the previously cleaned inside bal loon into the components to be jointed in such a position that is centered on the midline inside the electrofusion fitting when the wel...

Страница 20: ...at least to identify its cause Type of Error Description a Data Input Input Error Error while entering data with the alphanumeric and cursor keys Code Error Error while reading data from a bar code o...

Страница 21: ...current failure or if the current decreases by more than 15 per second for 3 seconds Excess Current The output current value is in excess possible causes short circuit in the heater coil or the weldin...

Страница 22: ...confirm your selection by pressing the START SET key The Service Report option is not important for normal operation In the scope of computer assisted unit service this report lists the events re late...

Страница 23: ...ing Unit The key technical information on the welding unit itself is displayed by pressing the key at the Enter Fitting Code screen They are the soft ware version the serial number of the unit the dat...

Страница 24: ...ained Important Non compliance with this provision will dispense the manufac turer from any warranty and liability claims for the unit and any consequential damage All machines that are new or newly p...

Страница 25: ...0 B User s Manual 8 4 Included in Standard Shipment 1 x Welding Machine upon reqiest P O Box 1108 655 Andover St Lawrence MA 01843 Tel 800 343 3618 781 321 5409 Fax 800 787 6861 Website www asahi amer...

Страница 26: ...44 Central 800 442 7244 West 800 282 7244 Fax 800 787 6861 www asahi america com asahi asahi america com P O Box 1108 655 Andover St Lawrence MA 01843 Tel 800 343 3618 781 321 5409 Fax 800 787 6861 We...

Отзывы: