If the position of the FSM’s clamping nut is uncomfortable, change it as follows:
1. Decide on desirable position of the nut and estimate the angle through which the FSM should be 

turned CW (see Figure 2-8).

2. Remove the FSM from the Victrix.
3. Using a screwdriver, remove the M2×2.5 screws (F, see Figure 2-7) and then unscrew the ring (E).

FIGURE 2-8. ESTIMATION OF THE FSM TURNING ANGLE

NUT

DESIRABLE POSITION 

OF THE NUT

CAUTION:

To loosen the ring (E, Figure 2-7), use the two auxiliary non-threaded holes (D). DO NOT 

USE the threaded ones.

4. Using a lathe or other precision cutting tool, cut the inside face of the ring (E, Figure 2-7). The 

value of cuts (in millimeters) should be equal to the value of the turning angle (in angular 

degrees) divided by 360°.

5. Screw the ring (E) into the FSM’s body with its cut end directed inwards. Tighten the screw.
6. After applying a small amount of thread lock to the threads, affix the ring (E) using the two 

M2×2.5 screws (F).

2.1.5  INSTALLING THE LIGHT SUPPRESSOR FOR A DAY SCOPE

The Light Suppressor for a Day Scope (A, Figure 2-9) slides over the eyepiece of your daytime 

scope (B). The suppressor can be used with scopes that have 40-43 mm eyepiece diameters and 

100-120 mm eye relief.
The suppressor can be adjusted for the eye relief of your scope by cutting the rubber at the desired 

distance (C).

FIGURE 2-9.  LIGHT SUPPRESSOR FOR A DAY SCOPE

A

B

C

Содержание VICTRIX

Страница 1: ...USER MANUAL VICTRIX THERMAL IMAGING CLIP ON SYSTEM...

Страница 2: ...on Regulations the International Economic Emergency Powers Act and various U S embargoes and sanctions AGM Global Vision products may not be exported re exported or transferred contrary to U S export...

Страница 3: ...Key Features 11 2 OPERATING INSTRUCTIONS 12 2 1 Installation and Mounting 12 2 2 Controls and Display Indicators 18 2 3 Operating Procedures 26 3 MAINTENANCE INSTRUCTIONS 29 3 1 Operator Troubleshooti...

Страница 4: ...TING THE FIREARM verify that your installation provides sufficient space between the eyepiece and the scope to account for the recoil generated by your rifle NOTE Give special attention to this warnin...

Страница 5: ...ing the batteries Thoroughly clean and dry all items before placing them into the storage case To avoid deformation or damage remove the light suppressor from the Victrix before placing the equipment...

Страница 6: ...cient thermal contrast between the target and background area or between the different parts of a target For example there would be a vast temperature contrast between the snow and any heat target suc...

Страница 7: ...tery pack also can be easily connected via an USB connector for a significant increase of operating time The quick release mount of the Victrix fits any Picatinny MIL STD 1913 or Weaver weapon rail Th...

Страница 8: ...TABLE 1 2 STANDARD COMPONENTS ITEM NO DESCRIPTION QUANTITY 1 Victrix Thermal Imaging Clip On system 1 2 Objective Lens Cap 1 3 Output Lens Cap 1 4 Mount 1 5 CR123A Lithium Battery 2 6 Light Suppressor...

Страница 9: ...e Victrix on the lenses of specified day scopes Includes a clamp with inserts that will fit 38 and 42 mm diameters 6106SM21 Front Scope Mount 3 A mounting system used to install the Victrix on the len...

Страница 10: ...harpness Electronic magnification Manual and Automatic Non Uniformity Calibration NUC Stadiametric rangefinder Defective pixels repair Current operational state information display battery status pale...

Страница 11: ...CR123A batteries C into the battery compartment Align the polarity symbols on the batteries with the polarity symbols on the device body D 3 Close the battery cover Turn the battery cover knob clockw...

Страница 12: ...ce in the axis heights of the Victrix and day scope above the weapon rail exceeds 3 mm you will need to replace the day scope mounting rings or monoblock The Victrix comes fully assembled with a Picat...

Страница 13: ...nt 2 1 3 CLAMPING DEVICE ADJUSTMENT To adjust the mount s clamping device do the following refer to Figure 2 5 1 Unlock the clamping device and remove the Victrix from the weapon 2 To tighten loosen t...

Страница 14: ...hows the Victrix TC50 640 installed on the lens of a day scope Install the Victrix on the lens of a day scope as follows refer to Figure 2 7 1 Using a 2 5 mm Allen key unscrew the M4 8 screws securing...

Страница 15: ...tool cut the inside face of the ring E Figure 2 7 The value of cuts in millimeters should be equal to the value of the turning angle in angular degrees divided by 360 5 Screw the ring E into the FSM...

Страница 16: ...cable of Digital Video Recorder WiFi Attachment or the Extended Battery Pack to the Victrix S620 universal connector Use the video cable plug A Figure 2 11 to connect an external video recorder monito...

Страница 17: ...ge NUC ON OFF Quick menu Exit Quick Menu Main menu Confirm selection 2 Up Button Real time image Bring out quick menu Enter main menu Quick menu Change parameters Main menu Change parameters 3 Down Bu...

Страница 18: ...utton in Up Down Left Right To toggle between the functions below press Left or Right button when Quick menu is in display If select of Zoom Palette Brightness Contrast Sharpness functions do not take...

Страница 19: ...stances for the three objects There are three pre set reference objects Object 1 height 0 3 m Object 2 height 0 7 m Object 3 height 1 7 m The lower fixed bar under the object automatically appear on d...

Страница 20: ...tomatically AUTO NUC Press the Up Down button to turn Automatic Non Uniformity Calibration On Off In the automatic mode the need for calibration is based on software algorithm calibration starts autom...

Страница 21: ...riflescope its parallax and shooting distance The Victrix ensures the shooting precision tolerance within 3 to 7 cm at 100 m To achieve better accuracy use Alignment Correction option in the main menu...

Страница 22: ...to move between X Y and EXIT Press Up button to change positive value X Y and press Down button to change negative value X Y 6 Press EXIT Up or Down button to save settings 7 Check if the value was s...

Страница 23: ...ay scope Refer to Parts 2 1 2 2 1 4 for installation procedures 3 Verify that the Victrix is securely mounted to the weapon or scope 4 Remove the protective caps 5 Point the equipment at an object 6 A...

Страница 24: ...using the MAIN MENU See Part 2 2 2 Using the MAIN MENU 11 To align the barrel of the weapon place the reticle on the desired target To allow for the bullet s travel i e bullet drop windage and the ta...

Страница 25: ...IVE ACTION The Victrix fails to activate Batteries are missing or improperly installed Insert batteries or install correctly Batteries are dead Replace the batteries Batteries surfaces or contacts are...

Страница 26: ...om the equipment using only a clean soft cloth 2 Moisten the cloth with fresh water and gently wipe the external surfaces except for optical surfaces 3 Dry any wet surfaces except for optical surfaces...

Страница 27: ...only to the original purchaser Any breach of this warranty shall be enforced unless the customer notifies AGM Global Vision at the address noted below within the applicable warranty period The custome...

Страница 28: ...Please include a letter that indicates your RMA the Customer s Name a Return Address reason for the return contact information valid telephone numbers and or an e mail address and proof of purchase th...

Страница 29: ...sighting Accuracy Factory aligned to 1 MOA or better Retention Permanent to within 2 MOA or better Repeatability Within 2 MOA Interfacing Micro USB Power bank 5V Universal S620 connector Power In Anal...

Страница 30: ...ply via S620 universal connector TABLE 5 4 MECHANICAL DATA ITEM VICTRIX TC38 VICTRIX TC50 Weapon Mount Type Picatinny MIL STD 1913 and Weaver Rails Overall Dimensions 181 84 64 mm 7 1 3 3 2 5 in 190 8...

Страница 31: ...ta Artemis 2000 4x32 42 0 Leupold Mark 4 3 9x36 Leupold Mark 4 2 5 8x36 Kahles 4x36 Front Scope Mount 3 46 7 40 42 Leupold 3 5 10x40 Leupold VX II 3 9x40 48 0 Zeiss 1 5 6x42 Swarovski PV N 2 5 10x42 4...

Страница 32: ...t be removed in order to replace authorized parts The PART NO column indicates the primary number used by the manufacturer to identify an item which controls the design and characteristics of that ite...

Страница 33: ...ens Assembly 38mm GOL38OBLAS 5 Battery Cap AGMTIDBCP 6 Connectors Cap AGMTIDCNCP 7 Output Lens Cap AGMANOPLC6 8 Output Lens Assembly 50mm AGMANF25OLA 8 Output Lens Assembly 38mm AGMANF238LA 9 Side Pic...

Страница 34: ...34 AGM Global Vision NOTE...

Страница 35: ...35 Victrix USER MANUAL NOTE...

Страница 36: ...ain Street PO Box 962 Springerville AZ 85938 USA Tel 1 928 333 4300 Fax 1 480 393 4882 info agmglobalvision com www agmglobalvision com EUROPEAN OFFICE Andrey Lyapchev 7 Sofia P C 1756 Bulgaria Tel 44...

Отзывы: