Agilent Technologies U5309A Скачать руководство пользователя страница 13

Step 4: Install the Module

Note that the U5309A is optionally supplied with a card retainer (included if ordered as U5300A-001, or available
separately by ordering U1092-CRM) which is able to pick up on slots at the end the full-length PCIe slot and
provide additional support for the module. Use of this card retainer is highly recommended, in particular when the
PC motherboard is oriented vertically. However if your PC hardware does not provide end slots, the card retainer
may be removed from the module.

It is also possible to reverse the orientation of the fan assembly in the case that two modules must be placed in
adjacent slots, or other PC hardware obstructs the fitting. These three procedures are detailed below.

Fitting the module with the optional card retainer into your PC

1. Loosen (but do not remove) the screw (A) holding the rear card retainer, and slide it towards the fans.
2. Insert the module into the PCIe slot of the PC, ensuring that it is fully seated into the PCIe bus connector.
3. Fix the module to the PC either by fitting a screw, or by using a method integral to your PC model.
4. Fully extend the card retainer and ensure that it is inside the PC chassis support slot.
5. Tighten the screw (A) (0.5 Nm torque).

Figure 1 - Diagram showing fan/support assembly fixings (U5303A shown as example)

Agilent U5309A Startup Guide

13

Содержание U5309A

Страница 1: ...Agilent Technologies PCIe High Speed Digitizer 2 or 8 channels 8 bit up to 2 GS s DC up to 500 MHz bandwidth with custom firmware support suited for embedded OEM applications U5309A Startup Guide...

Страница 2: ...or contract clause Use duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will recei...

Страница 3: ...the voltage being measured The instrument and accessories must be used in accordance with its specifications and operating instructions or the safety of the equipment may be impaired Do not exceed th...

Страница 4: ...rated from normal waste for disposal Reference WEEE Directive 2002 96 EC This symbol indicates the time period during which no hazardous or toxic substance elements are expected to leak or deteriorate...

Страница 5: ...ESD Precautions 9 Inspect for Damage 9 Return a Module for Service 9 Step 2 Verify U5309A Shipment Contents 10 Step 3 Install the Software 11 System Requirements 11 Hardware Requirements 11 Step 4 In...

Страница 6: ...Documentation Map Documentation Map 6 U5309A Startup Guide...

Страница 7: ...your product and at www agilent com find U5309A Select Technical Support Manuals l U5309A User Manual l Help systems for the Agilent device drivers IVI C and IVI COM and LabVIEW G l Product specificat...

Страница 8: ...8 U5309A Startup Guide...

Страница 9: ...work station when working on circuitry with a voltage potential greater than 500 volts Inspect for Damage After unpacking a module inspect it for any shipping damage Report any damage to the shipping...

Страница 10: ...ial number and model number Step 2 Verify U5309A Shipment Contents The following items are also included with your U5309A PCIe High Speed Digitizer order Part Number Quantity Description U5309A 1 PCIe...

Страница 11: ...ou may not need this amount of available disk space Hardware Requirements A PC running one of the above operating systems Recommended models are HP Z420 or Dell T3610 Install the Software Agilent IO L...

Страница 12: ...e floppy drive power connector simply attach this If your PC does not have a free connector of this type you may use one of the two supplied adapters l If your PC has spare 4 pin Molex power connector...

Страница 13: ...embly in the case that two modules must be placed in adjacent slots or other PC hardware obstructs the fitting These three procedures are detailed below Fitting the module with the optional card retai...

Страница 14: ...the fan assembly 1 Remove the 4 screws B nearest to the front of the fan unit 2 Slide the fan unit approximately 15 mm to the rear until it clears the circuit board disconnect the power cables and ro...

Страница 15: ...onfigurable Input Output signal 3 3 V CMOS and TTL compatible CLK IN MMCX External clock input AC coupled and 50 terminated signal level 5 to 15 dBm Please refer to datasheet for details REF IN MMCX E...

Страница 16: ...US Module status White blinking Firmware initialization in progress Green blinking Module initialization in progress Yellow blinking Warning Red blinking Error Green OK ready Note If warning or error...

Страница 17: ...and other operational verification procedures Agilent U5309A Instrument Properties The instrument properties may be viewed by clicking on the desired instrument and then on the Instrument Properties t...

Страница 18: ...age level at the INPUT connector 3 4 V DC 1 Configure the RF Generator to produce a Sine signal with a Frequency of 1 0 MHz an Amplitude of 300 mV rms 2 55 dBm 2 Connect the Signal Generator output to...

Страница 19: ...19 U5309A Startup Guide...

Страница 20: ...iness goals increased confidence in uptime reduced cost of ownership Agilent Advantage Services www agilent com find AdvantageServices PCI Accurate measurements throughout the life of your instrument...

Отзывы: