background image

TriScroll 320 Series Vacuum Pump 

This page intentionally left blank.

                 

Pg 2/3

 

 

 

 

      

Vacuum Products Division      

      

Request 

for 

Return 

Form 

 

 

 

 

 

 

 

 

 

            (Health and Safety Certification) 

Please read important policy information on Page 3 that applies to all returns. 

1) CUSTOMER INFORMATION 

Company Name:  

   

 

Contact Name:  

 

Tel: 

         

                                     Email: 

         

                                                Fax: 

         

 

Customer Ship To: 

         

  

Customer Bill To: 

         

   

 

 

         

 

         

 

 

 

Europe only:   

VAT reg. Number:  

 

USA/Canada only

:   

 Taxable    

 Non-taxable 

 

 

                  

2) PRODUCT IDENTIFICATION 

Product Description 

Agilent P/N 

Agilent S/N 

Original Purchasing Reference 

 

 

 

 

 

 

 

 

 

 

 

 

 
3) 

TYPE OF RETURN  

(

Choose one from each row

 and supply Purchase Order if requesting a billable service) 

 

   

3A.   

 Non-Billable       

 

 Billable                 New PO # (hard copy must be submitted with this form): 

         

 

 

   

3B

.   

Exchange    

Repair     

Upgrade    

Consignment/Demo     

Calibration    

Evaluation    

Return for Credit

 

 

  

4) HEALTH and SAFETY CERTIFICATION

 

AGILENT TECHNOLOGIES CANNOT ACCEPT ANY PRODUCTS CONTAMINATED WITH BIOLOGICAL OR EXPLOSIVE HAZARDS, 
RADIOACTIVE MATERIAL, OR MERCURY AT ITS FACILITY.   
Call Agilent Technologies to discuss alternatives if this requirement presents a problem. 

 

The equipment listed above (check one): 
 

 HAS 

NOT

 pumped or been exposed to any toxic or hazardous materials.  OR 

 

 

HAS

 pumped or  been exposed to the following toxic or hazardous materials.  If this box is checked, the following  

 

 

information must also be filled out.   Check boxes for all materials to which product(s) pumped or was exposed: 

 

    

Toxic  

  Corrosive 

  

 Reactive 

 

 Flammable 

   

 Explosive 

   

 Biological      

 Radioactive 

 

List all toxic/hazardous materials. Include product name, chemical name, and chemical symbol or formula: 

         

 

________________________________________________________________________________________________________ 

NOTE: 

If a product is received at Agilent which is contaminated with a toxic or hazardous material that was not disclosed, 

the customer will be held responsible

 for all 

costs incurred to ensure the safe handling of the product, and 

is liable 

for any harm or injury to Agilent employees as well as to any third party occurring as a result of 

exposure to toxic or hazardous materials present in the product. 

Print Name: 

         

    

 

              Authorized Signature: ………………………. 

 

   Date: 

         

 

5) FAILURE INFORMATION: 

Failure Mode (REQUIRED FIELD.  See next page for suggestions of failure terms): 

         

 

Detailed Description of Malfunction: (Please provide the error message) 

 

Application (system and model): 

 

 

 I understand and agree to the terms of Section 6, Page 3/3. 
 Print Name:

 

         

    

 

              

Authorized Signature: ………………………. 

 

   Date: 

         

 

Содержание TriScroll 320 Series

Страница 1: ...INSTALLATION AND OPERATION MANUAL Vacuum Products Division TriScrollTM 320 Series Dry Scroll Vacuum Pump Manual No 699904342 Revision F October 2014...

Страница 2: ...Copyright 2014 Agilent Inc TriScroll 320 Dry Scroll Vacuum Pump TriScroll is a trademark of Agilent Inc...

Страница 3: ...earing Purge 9 Purge Kit 9 Troubleshooting 10 Maintenance 11 General Information 11 Related TriScroll Manuals 11 Maintenance and Tooling Kits 11 Factory Service Options 12 Accessories 12 Contacting Ag...

Страница 4: ...TriScroll 320 Series Vacuum Pump This page intentionally left blank...

Страница 5: ...ocol Storage When transporting and storing the pump the following environmental requirements should not be exceeded Preparation for Installation The pump is supplied in a special protective packing If...

Страница 6: ...ance with specific national and local standards Temperature 5 C to 40 C 41 F to 104 F Relative humidity 0 to 95 non condensing CAUTION As supplied from the factory the pump is configured for low volta...

Страница 7: ...n Female 1 4 National Pipe Thread NW16 adapter provided Gas ballast Female 1 4 National Pipe Thread 40 Micron sintered filter provided Ambient operating temperature 5 C to 40 C 41 F to 104 F Storage t...

Страница 8: ...TriScroll 320 Series Vacuum Pump 4 Figure 1 Interface Drawing with Dimensions Figure 2 Pumping Speed Curves...

Страница 9: ...13 Motor Electrical Cover Unpacking and Inspection The shipping container is a double carton 1 After opening the outer box remove the foam packing 2 Slit open the inner box 3 Lift the pump with the p...

Страница 10: ...er capacity The circuit breaker must be suitably located and easily reached The circuit breaker must be marked at the disconnecting device for the equipment with the on off symbol I O and meet the rel...

Страница 11: ...ct the motor to match your supply voltage Two options are available to strain relieve the electrical supply cable The cable can be mechanically held under the electrical cover in the groove provided T...

Страница 12: ...the vacuum chamber Use a bellows to provide both vibration isolation and strain relief between the pump and the vacuum chamber Pump Exhaust A female 1 4 National Pipe Thread exhaust fitting is located...

Страница 13: ...Scroll motor s inter nal thermal switch to actuate the VPI Valve Gas Ballast The gas ballast port item 9 on Figure 3 on page 5 is sealed on the TriScroll 320 For applications where a lot of water is b...

Страница 14: ...power supply cable Defective motor Inspect Contact Agilent Poor ultimate pressure System leak Locate and repair leak Water in pump Flush pump with air or dry nitrogen Gas ballast plugged Replace breat...

Страница 15: ...maintenance on TriScroll pumps is provided in kit form A description of each kit and ordering information is provided in Table 6 Table 5 Other Related Manuals Title Applicable TriScroll Model Part Num...

Страница 16: ...anual Contacting Agilent In the United States you can contact Agilent Customer Service at 1 800 882 7426 See the back cover of this manual for a listing of our sales and service offices Visit our web...

Страница 17: ...re product e g inlet screens vent valves x Prior to shipment drain any oils or other liquids purge or flush all gasses and wipe off any excess residue x If ordering an Advance Exchange product p pleas...

Страница 18: ...or been exposed to any toxic or hazardous materials OR HAS pumped or been exposed to the following toxic or hazardous materials If this box is checked the following information must also be filled ou...

Страница 19: ...ther Vacuum leak Other Section 6 ADDITIONAL TERMS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division Produc...

Страница 20: ...TriScroll 320 Series Vacuum Pump This page intentionally left blank...

Страница 21: ......

Страница 22: ...n 54 10040 Leini Torino ITALY Tel 39 011 997 9111 Fax 39 011 997 9350 Toll Free 00 800 234 234 00 Japan Agilent Technologies Japan Ltd Vacuum Products Division 8th Floor Sumitomo Shibaura Building 4 1...

Отзывы: