:FILTer[:LPASs][:STATe]
OUTPut[1]:FILTer[:LPASs][:STATe] <
mode
>
enables or disables the output filter.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<
mode
>
boolean
OFF | 0 | ON | 1
none
Comments
•
Executable when Initiated: Yes
•
Coupling Group: None
•
Related Commands:
OUTPut[1]:FILTer[:LPASs]:FREQuency
•
*RST Condition:
OUTPut1:FILTer:LPASs:STATe OFF
Example
Enabling the 10 MHz Low-pass Filter
OUTP:FILT:FREQ 10 MHZ
Selects 10 MHz output filter.
OUTP:FILT ON
Enables output filtering.
:IMPedance
OUTPut[1]:IMPedance <
impedance
>
sets the Agilent E1445A’s output
impedance to either 50
Ω
or 75
Ω
.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<
impedance
>
numeric
50 | 75 | MINimum | MAXimum
Ohms
MINimum selects 50
Ω
output impedance; MAXimum selects 75
Ω
.
Comments
•
Executable when Initiated: Yes
•
Coupling Group: Voltage
•
Related Commands:
OUTPut[1]:LOAD
,
OUTPut[1]:LOAD:AUTO
•
*RST Condition:
OUTPut1:IMPedance 50
Example
Setting 75
Ω
Output Impedance
OUTP:IMP 75
Sets 75
Ω
output impedance.
OUTPut[1]
Chapter 8
Command Reference 309
Содержание E1445A
Страница 2: ......
Страница 14: ...Notes 12 Agilent E1445A User s Manual Contents...
Страница 18: ...Notes 16 Agilent E1445A Arbitrary Function Generator User s Manual...
Страница 19: ...Notes Agilent E1445A Arbitrary Function Generator User s Manual 17...
Страница 20: ...Notes 18 Agilent E1445A Arbitrary Function Generator User s Manual...
Страница 54: ...Notes 52 Getting Started Chapter 1...
Страница 84: ...Notes 82 Generating Standard Waveforms Chapter 2...
Страница 204: ...Notes 202 Arming and Triggering Chapter 5...
Страница 432: ...Figure 9 1 E1445A Status Groups and Associated Registers 430 AFG Status Chapter 9...
Страница 446: ...Notes 444 AFG Status Chapter 9...
Страница 464: ...Notes 462 Agilent E1445A Specifications Appendix A...
Страница 534: ...Notes 532 Agilent E1445A User s Manual Index...