4-105
Screens
Pwr Ramp: Pulse (Option 006 Only)
4. Meas Sync (Sync
Status)
This field displays any errors that occurred while trying to synchronize to the
demodulated data.
See Also
Making Measurements: Solving Problems Messages
5. Pulse On/Off Fall
This field displays the measured amplitude at the fall-position time relative to the
average On power over the useful bits in the measured burst.
See Also
Keys: ON/OFF, HI LIMIT, LO LIMIT, REF SET, AVG,
METER, Units
NOTE
The Pulse On/Off Ratio measurement requires the use of measurements on three
bursts: the first is to establish the reference amplitude level of the burst, the second is
to measure the rise portion of the burst, and the third is to measure the fall portion of
the burst. Between the measurements the analyzer amplitude and trigger delay is
internally changed for the following measurement. Since RF Rise triggering is based
on a variable rising edge of the incoming signal, the measurement result cannot be
considered valid, unless the burst timing is consistent.
NOTE
When the Test Mode or CW Generator mode is selected on the cell control screen,
the RF rise trigger is automatically selected.
6. Pulse On/Off Rise
This field displays the measured amplitude at the rise-position time relative to the
average On power over the useful bits in the measured burst.
See Also
Keys: ON/OFF, HI LIMIT, LO LIMIT, REF SET, AVG,
METER, Units
7. Rise Pos
This field selects the time (relative to the center of bit zero) that the amplitude on the
amplitude envelope will be measured.
Range
−
56.0
µ
s to 0.0
µ
s.
8. Single/Cont
Single allows one test to be performed. Cont allows testing to automatically repeat.
Содержание 8922M
Страница 8: ...Contents Contents 6...
Страница 21: ...1 1 1 Installing Your Agilent 8922M S...
Страница 24: ...1 4 Installing Your Agilent 8922M S Fuses and Power Cords Power Cords Agilent Part Agilent...
Страница 29: ...2 1 2 Making Measurements...
Страница 59: ...2 31 Making Measurements If You Have Problems with a Measurement Figure 2 16...
Страница 61: ...2 33 Making Measurements If You Have Problems with a Measurement Trigger Range For Pulsed RF...
Страница 75: ...2 47 Making Measurements Advanced Features...
Страница 76: ...3 1 3 Verifying Performance...
Страница 106: ...3 31 Verifying Performance Agilent Technologies 8922M S Specifications...
Страница 224: ...4 118 Screens Service Service This screen is documented in the service documentation To escape press PREV...
Страница 235: ...4 129 Screens Tests Tests Instrument BASIC Refer to chapter 8 Instrument BASIC for information about the Tests Screen...
Страница 236: ...4 130 Screens Tests...
Страница 237: ...5 1 5 Keys...
Страница 238: ...5 2 Keys Key Map Key Map...
Страница 275: ...6 27 Connectors Timing Diagrams Timing Diagrams Figure 6 2 Digital Demodulation Timing Specification Table...
Страница 276: ...6 28 Connectors Timing Diagrams Figure 6 3 Digital Demod Timing Diagram...
Страница 277: ...6 29 Connectors Timing Diagrams Figure 6 4 Frequency Hop Timing Specification Table...
Страница 278: ...6 30 Connectors Timing Diagrams Figure 6 5 RF Generator Hop Address Source Ext Timing Diagram...
Страница 279: ...6 31 Connectors Timing Diagrams Figure 6 6 RF Analyzer Hop Address Source Ext Timing Diagram...
Страница 280: ...6 32 Connectors Timing Diagrams Figure 6 7 RF Generator Hop Address Source Int Timing Diagram...
Страница 281: ...6 33 Connectors Timing Diagrams Figure 6 8 RF Analyzer Hop Address Int Timing Diagram...
Страница 282: ...6 34 Connectors Timing Diagrams Figure 6 9 Reset Hop Once Address Source Int Timing Diagram...
Страница 283: ...6 35 Connectors Timing Diagrams Figure 6 10 Reset and Hold Hop Address Source Int Timing Diagram...
Страница 284: ...6 36 Connectors Timing Diagrams Figure 6 11 Hop Inhibit Address Source Int Timing Diagram...
Страница 297: ...8 1 8 Instrument BASIC...
Страница 341: ...A 1 A APPENDIX A...
Страница 364: ...A 24 APPENDIX A Protocol Log of a Typical Call...
Страница 365: ...B 1 B Glossary...
Страница 370: ...B 6 Glossary...