Specifications
Performance specifications are warranted over the ambient temperature range of 0 to 40 oC. Unless
otherwise noted, specifications are per phase for a sinewave with a resistive load at an output frequency
range of 45 Hz to 5 kHz (45 Hz-1 kHz, Agilent 6843A) after a 30-minute warmup.
Table A-1. Performance Specifications
1
Parameter Agilent 6814B Agilent 6834B Agilent 6843A
Phases: 1 3
1
1
Maximum Output Ratings
rms Voltage
2
:
150 V low range;
300 V high range
Power: 3 kVA 1.5 kVA/phase 4.5 kVA 4.8 kVA
rms Current: 20 A low range 10 A low range 30 A low range 32 A low range
10 A high range 5 A high range 15 A high range 16 A high range
Repetitive peak Current: 80 A low range 40 A low range 120 A low range 96 A low range
40 A high range 20 A high range 60 A high range 48 A high range
Crest Factor (current): 4
4
4
3
Output Frequency Range: 45 Hz
−
5 kHz 45 Hz
−
1 kHz
Constant Voltage Ripple and Noise
−
60 dB (20 kHz
−
10 MHz)
Load Regulation:
Line Regulation:
0.5%
0.1%
Maximum Total Harmonic Distortion: 1% (45 Hz
−
1 kHz);
1% + 1%/kHz (>1 kHz
−
5 kHz)
Programming Accuracy (@ 25oC
±
5oC)
rms Voltage: 0.15% + 0.3 V (45
−
100 Hz)
0.5% + 0.3 V (>100
−
500 Hz)
1% + 0.3 V (>500
−
5 kHz)
Frequency: 0.01% + 10
µ
Hz
Phase: (Agilent 6834B in 3-phase
mode)
N/A
0.1
º
(45-100 Hz)
1
º
(>100
−
1 kHz)
1
º
+ 1%/kHz
(>1k
−
5 kHz)
N/A N/A
Measurement Accuracy (@25oC
±
5oC)
rms Voltage 0.05%+ 250 mV (45 Hz
−
1 kHz)
0.05% + 0.1%/kHz + 250 mV (>1 kHz
−
5 kHz)
0.05% + 250 mV
rms Current 0.1% + 50 mA 0.1% + 25 mA 0.1% + 50 mA 0.1% + 50 mA
Frequency: 0.01% + 0.01Hz 0.01% + 0.01Hz 0.01% + 0.01Hz 0.01% + 0.01Hz
Power (VA): 0.15% + 5 VA 0.15% + 3 VA 0.15% + 5 VA 0.15% + 9 VA
Power (Watts): 0.15% + 5 W 0.15% + 3 W 0.15% + 5 W 0.15% + 9 W
Power Factor: 0.01 0.01 0.01 0.01
1
Specifications subject to change without notice.
2
From line to neutral on Agilent 6834B