3 - Troubleshooting
34
"H" From Sheet 4
Connect an external power
supply across the output (+ to
+, - to -). Program the UUT
voltage to 0V, Output ON and
the test supply to 5V and 2A
Meter indicates 5V,
-1.5A
?
Unit operating normally
Yes
U321A-1 -0.4V
?
No
Check U321A, D327,
R324 and R362
No
U308A-1 -1.5V
?
Yes
Check U308A, Q306,
D319 and associated
circuits
No
Check Q306, Q309,
R436 and -Rail
Yes
Figure 3-1 Sheet 12. Slow Downprogrammer