Switches
•
8768K
Attenuators
•
8494G/H
•
8496G/H
•
8495K, 8497K
001, 101
4
Yes
Yes
Switches
•
8768M
Attenuators
•
84904K/L/M
•
84906K/L
•
84908M
001
4
Yes
Yes
Switches
•
87104A/B/C/D
•
87204A/B/C
•
L7104A/B/C
•
L7204A/B/C
201, 601
4
**
Yes
Yes
Switches
•
8769K
101
5
Yes
Yes
Switches
•
8769M
701
5
Yes
Yes
Switches
•
87106A/B/C/D
•
87206A/B/C
•
L7106A/B/C
•
L7206A/B/C
•
87406B, 87606B
201, 401
6
††
Yes
Yes
* Type of interface cable required depends on the DC connector on the switching device
† One channel represent control with one pushbutton
‡ Ensure switch is equiped with current interrupt (option 403) to protect switch from overhetaing and
destruction as this switch cannot withstand continuous current
**If option 601 is used, number of channels required is 5, to cater for open all path function controlled via
S9/S0
††If option 401 is used, number of channels required is 7, to cater for open all path function controlled via
S9/S0
Table 5
Summary of switches and attenuators connections to 11713B/C
Содержание 11713B
Страница 1: ...Agilent Technologies Agilent 11713B C Attenuator Switch Drivers Operating and Service Manual ...
Страница 12: ...12 11713B C Operating and Service Manual ...
Страница 24: ...24 11713B C Operating and Service Manual 1 Introduction ...
Страница 43: ...Specifications 3 11713B C Operating and Service Manual 43 Declaration of Conformity ...
Страница 44: ...44 11713B C Operating and Service Manual 3 Specifications ...
Страница 64: ...64 11713B C Operating and Service Manual 5 Local Operations ...
Страница 88: ...88 11713B C Operating and Service Manual 7 Remote Interface Configurations ...
Страница 104: ...104 11713B C Operating and Service Manual 8 Replacing Major Assemblies ...
Страница 114: ...114 11713B C Operating and Service Manual 9 Servicing the Attenuator Switch Driver ...