3. Turn the red Thermostat Set-Point dial clockwise until the heater turns on.
4. Reset the red Thermostat Set-Point dial to the previous setting.
5. Close the M5500 electrical enclosure door and lock the hasp with a slotted
screwdriver.
Change Thermostat Setting:
NOTE:
It is the owner’s responsibility to set the thermostat based upon the climate
conditions of the installed location. The default setting of 50º F is adequate for
outside temperatures down to 0º F. If operating below this temperature, the set-
point should be increased. Consult AGF for set-point guidelines.
1. Disconnect electrical power to the M5500.
2. Using a slotted screwdriver, unlock and open the
door of the M5500 electrical enclosure.
3. Turn the red Thermostat Set-Point Dial clockwise
or counterclockwise to the desired setting.
4. Take note of the new thermostat set-point.
Thermostat Set-Point: __________________
5. Close the M5500 electrical enclosure door and
lock the latch with a slotted screwdriver.
6. Apply power to the M5500.
MAINTENANCE LOG
Initials
Maintenance Description
Date
_________ ________________________________________________ ________
_________ ________________________________________________ ________
_________ ________________________________________________ ________
_________ ________________________________________________ ________
_________ ________________________________________________ ________
_________ ________________________________________________ ________
_________ ________________________________________________ ________
_________ ________________________________________________ ________