Attaching the Eave Angle to the Sidewall Sheet
The eave angle secures the bottom of the roof panels to the bin eave.
What You Should Know
Eave angles are bolted to the
outside
surface of the sidewall and will overlap each section.
1. Locate the top inside stiffener (B) and align the holes of the first eave angle (A) to the sidewall sheet
with the holes of the top inside stiffener (B).
IMPORTANT:
Make sure to align the center of the eave angle tab (C) a distance of
9.375 in
. from
the center of the top inside stiffener when assembling to the sidewall sheet. This is
very important to ensure the roof panels align properly with the rafters.
Figure 8-3
Eave angle alignment
A
First Eave angle (CTR-0720)
C
Eave angle tab
B
Top inside stiffener
2. Install flange bolts (D) and flange nuts (B), leaving the end holes open.
NOTE:
The quantity of flange bolts (D) and flange nuts (B) may vary, depending on the sidewall
punch pattern.
3. Install the second eave angle (C) overlapping the first eave angle (A).
4. Install the flange bolts (D) and flange nuts (B), leaving the last hole open for the next eave angle to
be installed.
NOTE:
The quantity of flange bolts (D) and flange nuts (B) may vary, depending on the sidewall
punch pattern.
5. Bend the eave angle tabs (G) upward to conform with each roof panel rib.
84
Pneg-4460A
60 Ft Diameter 40-Series Bins
Содержание GSI 40 Series
Страница 6: ...NOTES 6 Pneg 4460A 60 Ft Diameter 40 Series Bins...
Страница 14: ...NOTES 14 Pneg 4460A 60 Ft Diameter 40 Series Bins...
Страница 28: ...NOTES 28 Pneg 4460A 60 Ft Diameter 40 Series Bins...
Страница 130: ...NOTES 130 Pneg 4460A 60 Ft Diameter 40 Series Bins...