© 2014 AGCO Corporation
Header Calibration
Navigate to the header calibration menu
It is recommended to complete the header
calibration once all settings have been
optimized. Maintain pitch, cutterbar
pressure, automatic header and tilt
sensitivities, and ¼ open on accumulator
Follow the on-screen instructions and verify
all by-standers are clear of the header
before starting the header calibration
process.
Note: For DynaFlex and Command Corn
Heads LH and RH sensor voltages should
be above 1 V and under 4 V. Ex 1.3 V to
3.8 V. Tilt is above 5mA and under 19 mA.
29