41
SECURE MAINS CABLE USING ‘P’ CLIPS FOR LEFT HAND OR RIGHT HAND CABLE MANAGEMENT.
The method of connection to the mains electricity supply
must facilitate complete electrical isolation of the appliance,
by a multi-pole switch, having a contact separation of at least
3 mm on all poles.
The isolator should not be positioned immediately above the
cooker, but must be fitted within 2 metres of the appliance.
The isolator maybe separate from the connection point.
The mains connection point must be accessible within the
areas shown in
for cable routing
options.
For 2 or 3 phase installations an optional adaptor kit must be
obtained (Part No. AE4M280352).
Induction Hob
An additional,
separate single phase power supply
is
required. 230V ~ 50Hz, 13amp fused electrical supply.
22. Electrical connection
Fig. 22.1
Fig. 22.2
DESN 517652
DESN 517651
n
WARNING: This appliance must be earthed.
n
This appliance is designed for the voltage stated on
the rating plate, which is situated behind the plinth
cover.
n
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified person to avoid a hazard.
For the cooker
A 1PH 13 AMP 230V or 3PH 400V minimum 16A per phase
~ 50 Hz fused electrical supply is required adjacent to the
appliance. External wiring to the unit must be installed using
the mains cable provided, in accordance with the current
wiring regulations and any local regulations which apply.
If the cable is shortened, new ferrules must be fitted to the
stripped conductors.
450mm MA
X
2 metr
es
2 me
tres
WORKTOP
WORKTOP
THE MAINS SUPPLY MUST BE WITHIN THE ZONES SHOWN. IF A RECESSED
COOKER CONNECTION IS TO BE USED BEHIND THE APPLIANCE WITHIN THE
HATCHED AREA ALLOW A 5mm GAP AT REAR OF APPLIANCE.
Cable point for 3m long 13A cable supplying induction hob.
Cable point for 3m long 32A cable supplying main cooker.
THE MAINS SUPPLY MUST BE WITHIN THE ZONES SHOWN. IF A RECESSED COOKER CONNECTION IS TO BE
USED BEHIND THE APPLIANCE WITHIN THE HATCHED AREA ALLOW A 5mm GAP AT REAR OF APPLIANCE.
Cable point for 3m long 13A cable supplying induction hob.
Cable point for 3m long 13A cable supplying main cooker.
SECURE MAINS CABLE USING ‘P’ CLIPS FOR LEFT HAND OR RIGHT HAND CABLE MANAGEMENT.
WORKTOP
2.5 metr
es
450mm M
AX
2.5 metr
es
WORKTOP