CAUTION: THIS INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES
WITH THE NATIONAL FUEL GAS CODE ANSI.Z223.I AND NATIONAL ELECTRICAL CODE ANSI/NFPA70 (IN CANADA
CAN/CGA-B149) AND ONLY USED IN A WELL VENTILATED SPACE, READ THE INSTRUCTIONS BEFORE
INSTALLING OR USING THIS APPLIANCE.
PRIOR TO INSTALLATION, ENSURE THAT THE LOCAL DISTRIBUTION CONDITIONS (NATURE OF THE GAS AND
GAS PRESSURE) AND THE ADJUSTMENT OF THE APPLIANCE ARE COMPATIBLE.
THE ADJUSTMENT CONDITIONS FOR THIS APPLIANCE ARE STATED ON THE DATA PLATE.
THE GAS ADJUSTMENT CONDITIONS FOR THIS APPLIANCE ARE STATED ON THE DATA PLATE WHICH IS SITU-
ATED IN THE CENTRE VENT SLOT NEAR THE BASE OF THE FRONT PLATE.
CAUTION: THIS UNIT IS HEAVY, PROPER EQUIPMENT AND ADEQUATE MANPOWER MUST BE USED IN MOVING
THE RANGE TO AVOID DAMAGE TO THE UNIT OR THE FLOOR.
This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in
accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding
ventilation.
It should be in accordance also with any relevant requirements of the Gas Region and Local Authority.
The appliance and its individual gas shut off valve must be disconnected from the gas supply piping system during any
pressure testing of that system test pressure in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any
pressure testing of the gas supply system at test pressures equal to or less than 1/2 psi (3.5 kPa).
On completion test the gas installation for soundness and purge. Leak testing of the appliance shall be conducted according
to the manufacturers instructions.
NOTE:
Use soapy water solution on new gas connections to ensure there are no gas leaks.
WARNING: ELECTRIC SHOCK HAZARD
It is the customers responsbility to contact a qualified electrical installer to make sure the electrical installation is adequate
and in conformance with National Electrical Code ANSI/FPA 70- latest edition, and all local codes and ordinances.
Take special care when cutting holes in walls or floor. Electrical wires may be behind the wall or floor covering and could
cause an electrical shock if you touch them.
Locate any electrical circuits that could be affected by the installation of this product and disconnect power circuit.
Electrical grounding is required on this appliance.
Do not have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical
shock.
Do not use an extension lead with this appliance.
Check with a qualified electrician if you are not sure the appliance is properly grounded .
Failure to follow these instructions could result in death or serious injury.
In the interest of safety, due consideration must be given to the protection of the electric cable to the module.
INSTALLATION
10
Содержание DC3M
Страница 24: ...Fig 15 DESN 511617 BURNER CAP RETAINING LUGS Fig 15A DESN 513513 DESN 513898 Fig 15B 24...
Страница 26: ...Fig 17 Fig 18 DESN 511649 DESN 511650 26...
Страница 29: ...AGA TC DC INTEGRATED MODULE GAS HOB CIRCUIT DIAGRAM 29...
Страница 31: ...31...