background image

SECTION

PAGE

HEALTH & SAFETY

3

INSTALLATION REQUIREMENTS

3

DELIVERY REQUIREMENTS

3

APPLIANCE DIMENSIONS - AGA DC3

4

APPLIANCE DIMENSIOSN - AGA DC5 

5

CLEARANCES

6

TOP PLATE ADJUSTMENT - AGA DC3

7

POWER SUPPLY - AGA DC3

8

POWER SUPPLY - HOTCUPBOARD (AGA DC5)

8

MAINS CABLE ROUTING - AGA DC3

9

MAINS CABLE ROUTING - AGA DC5 

10

(HOTCUPBOARD OPTION)

EXTERNAL VENT MODELS - VENT PIPE CONNECTION

11

ROOM VENTED MODELS

12

OVEN VENTING SYSTEMS

13

HOTCUPBOARD INSTALLATION

14 - 18

HANDRAIL CONNECTION - AGA DC3

19

WIRING DIAGRAM - AGA DC3

20

WIRING DIAGRAM - HOTCUPBOARD OPTION

21

AGA DUAL CONTROL CHECKLIST

22

2

CONTENTS

Содержание DC3

Страница 1: ...part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by AGA For use in GB and IE Installation Guide AGA DUAL CONTROL Model No s DC3 DC5 Includes External Vent Room Vent Option ...

Страница 2: ...ER SUPPLY AGA DC3 8 POWER SUPPLY HOTCUPBOARD AGA DC5 8 MAINS CABLE ROUTING AGA DC3 9 MAINS CABLE ROUTING AGA DC5 10 HOTCUPBOARD OPTION EXTERNAL VENT MODELS VENT PIPE CONNECTION 11 ROOM VENTED MODELS 12 OVEN VENTING SYSTEMS 13 HOTCUPBOARD INSTALLATION 14 18 HANDRAIL CONNECTION AGA DC3 19 WIRING DIAGRAM AGA DC3 20 WIRING DIAGRAM HOTCUPBOARD OPTION 21 AGA DUAL CONTROL CHECKLIST 22 2 CONTENTS ...

Страница 3: ...ly wrapped INSTALLATION REQUIREMENTS THIS APPLIANCE MUST ONLY BE INSTALLED BY COMPETENT ENGINEERS WHO HAVE BEEN SPECIFICALLY FACTORY TRAINED ON THE PRODUCT AND WHO HAVE THE APPROPRIATE EQUIPMENT With specific exceptions the installing of any type of AGA cooker is subject to the respective directions contained in the current issue of the Building Regulations In addition planning permission may need...

Страница 4: ...al dimensional variations found in major castings In particular the width across the appliance recess could be critical RH SIDE OVEN VENT OPTION RH SIDE VIEW FRONT VIEW LH SIDE OVEN VENT OPTION LH SIDE VIEW PLAN VIEW MINIMUM WALL POSITION MINIMUM WALL POSITION APPLIANCE WEIGHT Excludes Packaging Model AGA Dual Control DC3 444kg A B C D E F G H J K L M N P Q R mm 987 948 910 680 1388 760 1145 698 1...

Страница 5: ...mm beyond the figures quoted above This allows safe margin to take into account the natural dimensional variations found in major castings In particular the width across the appliance recess could be critical APPLIANCE WEIGHT Excludes Packaging Model AGA Dual Control DC3 444kg Hotcupboard 110kg A B C D E F G H J K L M N P Q R mm 1478 948 910 680 1388 760 1145 698 116 10 536 849 30 634 448 813 ...

Страница 6: ...front plinth cover is removable and must not be obstructed by flooring or tiles If necessary the cooker must be raised by the thickness of the tiles to ensure the plinth can be removed Shims are provided to eliminate rocking Tiling When the cooker is to stand in a recess or against a wall which is to be tiled in no circumstances should the tiles overlap the cooker top plate access to remove the to...

Страница 7: ...te Adjustment AGA DC3 See Fig 3 In general adjustment of the top plate is to be avoided However minimum use of the top plate adjusters can be used to improve the alignment of the top plate 7 Fig 3 DESN 516751 ...

Страница 8: ...The mains connection point must be accessible within the areas shown in Fig 4A Page 9 for cable routing options For 2 or 3 phase installations an optional adaptor kit must be obtained Part No AE4M231226 POWER SUPPLY HOTCUPBOARD AGA DC5 THE HOTCUPBOARD ATTACHMENT REQUIRES AN INDEPEDENT SINGLE PHASE POWER SUPPLY WARNING THIS APPLIANCE MUST BE EARTHED THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED...

Страница 9: ...G AGA DC3 Fig 4 DESN 516643 MAINS CABLE FED FROM CONTROL TRAY LEFT OR RIGHT EXIT THROUGH DUCTING DEPENDENT UPON POSITION OF SUPPLY SOCKET 9 Fig 4A DESN 516105 THE MAINS SUPPLY CONNECT POINT MUST BE WITHIN THE ZONES SHOWN ...

Страница 10: ...PTION Fig 5 DESN 516644 MAINS CABLE FED FROM CONTROL TRAY LEFT OR RIGHT EXIT THROUGH DUCTING DEPENDENT UPON POSITION OF SUPPLY SOCKET 10 Fig 5A DESN 516447 THE MAINS SUPPLY CONNECT POINT MUST BE WITHIN THE ZONES SHOWN HOTCUPBOARD POWER SUPPLY ...

Страница 11: ... venting to the left hand side care must always be taken to ensure the vent pipe is fully lagged using insulation provided Where the vent pipe passes behind the hotcupboard ensure that the mains cable is kept away from the hot surface of the vent pipe Rear or right hand venting is preferable on AGA DC5 installations NOTE Vent pipe outlet under shroud to be left open DO NOT CAP OFF 11 NOTE THE VENT...

Страница 12: ...d that this model is fitted in conjunction with a cooker hood The AGA oven venting outlet is located on the top of the AGA between the two hotplates and is designed for venting the moisture from the ovens The cooker hood should be positioned not less than the minimum height as recommended by the manufacturer from the top of the AGA These are 650mm for AGA Rext 720 650mm for AGA 1000 SE ...

Страница 13: ... should be limited to 24V DC for ideal operating conditions Calculating the voltage for the particular pipework is as follows 1 Keep the pipe run as simple as possible avoid bends 2 Vertical risers are not permitted 3 Pipe run should be horizontal slight downwards slope towards the fan Minimum 12 volts for first metre of vent pipe run inclusive of 1 bend Each extra metre add 1 volt Each extra bend...

Страница 14: ...appliance to be slid onto its plinth when alongside the AGA DC3 without the top plates clashing The hotcupboard top plate should then be wound down to its correct height once the appliance is in its final position 1 Detach hotcupboard from plinth by removing two screws and tongue bracket from plinth See Fig 9 slide hotcupboard forwards and away from rear fixing bracket See Fig 10 ...

Страница 15: ... PLINTH BASE 11mm HEIGHT DIFFERENTIAL 3 Attach hotcupboard plinth to the AGA Dual Control plinth using M6 screws and washers provided See Fig 12 Attach locking screw and jacking screw into plinth Make sure at this stage that the jacking screw does not protrude beyond outer face of plinth Ensure locking screw is located into AGA DC3 plinth but not fully tightened A gap of approximately 3mm should b...

Страница 16: ... squarely jacking screws can be tightened until they just make contact with the AGA Dual Control plinth and locking screws can now be tightened Fig 13 DESN 516551 USE STRAIGHT EDGE ACROSS BOTH PLINTHS TO ENSURE PLINTHS ARE ALIGNED SQUARELY Fig 14 DESN 516553 16 5 Front jointing bracket can now be hooked into place over the two pot magnets This will latch the two plinths together See Fig 14 ...

Страница 17: ...d onto plinth until rear tongue bracket engages fully into rear of base slot See Fig 15 Ensure the appliance is aligned squarely with the plinth then proceed to engage the front tongue bracket into the slot on the underside of the base plate Once satisfied that the front tongue bracket is engaged fully lock it into place by tightening the two M6 screws fully Ensure that the electrical cable does n...

Страница 18: ...and and centre fixing studs Once the assembly has been fitted to the AGA appliance fit the handrail endcaps ensuring the handrail is evenly spaced at each end The endcaps should be carefully pushed into place until they sit flush with the outside face of each bracket The handrail can now be locked into place using the grub screws on the underside of the handrail brackets Finally fit plinth facia o...

Страница 19: ...brackets endcaps and handrail require assembly Locate endcaps onto handrail place brackets over endcaps and then slide complete assembly onto locating studs Once assembly is correctly located lock into position with grub screws located on underside of handrail ...

Страница 20: ...WIRING DIAGRAM AGA DC3 20 Fig 20 ...

Страница 21: ... WIRING DIAGRAM AGA DC5 HOTCUPBOARD OPTION CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING ...

Страница 22: ...l measurements can be made through small holes in the cover Record voltage l Measure vent pipe run and calculate fan speed voltage Ensure vent pipe routing complies with the Installation Instructions Record routing Record vent speed voltage l Turn on all cooking zones and vent fan Raise hotplate lids to avoid staining l After 1 hour check hotplate temperatures approx 1 Hotspot 330 380 C 2 Simmersp...

Страница 23: ...23 ...

Страница 24: ... continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time Manufactured by AGA Rangemaster Station Road Ketley Telford Shropshire TF1 5AQ England www agaliving com www agacookshop co uk ...

Отзывы: