12
INSTALLING THE POWER MODULE
Placing power module on top of cabinet:
Place module on top of the cabinet with rear shoulder
screws resting on the locator brackets behind the front
slots. Slide module toward the rear of the cabinet until the
rear shoulder screws engage the slots in the rear of the
brackets. Rest the front shoulder screws into the front slots
of the brackets.
Check to make sure wiring and ice maker tubing is clear
and not interfering with module seal. Do NOT start product
during construction, as dust can block module condenser
coils. If dust accumulates on coils, vacuum immediately,
using a soft brush attachment.
NOTE
Figure 14
Rear
shoulder
screw-
Front
shoulder
screw-
!
WARNING
TIPPING HAZARD
When installed the power module is not fas-
tened to the cabinet. It must be removed
when the cabinet is tipped or transported.
!
WARNING
EXCESSIVE WEIGHT HAZARD
Use two or more people to move product.
Failure to do so can result in back or other injury.
!
WARNING
EXPLOSION HAZARD
Do not operate the refrigerator/freezer in the
presence of explosive chemicals or fumes.
-Junction box
-Cabinet leads
-Power
cord
Power module on
top of cabinet-
Figure 15
Power module electrical connections:
Make electrical connections from the top of the lower
cabinet to the junction box at left side of module. With ice
maker, be sure to plug the ice maker line into the module,
and the solenoid valve as well. See module diagram Figure
15.
Run the power cord in front of power module on top of cabi-
net around the right side of power module to the electrical
outlet. See Figure 15.
Ice
maker
leads-
Water
valve-