OptRx uses sensors, usually mounted on the sprayer’s booms, to assess reflected light to determine plant vigor. It assigns 
numeric values to the varying levels of vigor to create a Vegetative Index (VI). Using the VI, OptRx calculates nitrogen 
application rates, to apply a variable rate on the go. OptRx creates nitrogen rates either by using the N Algorithm or by 
using the user defined Application Rate Table. OptRx can also be used for scanning purposes.

μ

Attention: Proper care of sensor will ensure accuracy and dependability.

Sensor is designed with a vent (A) to 
prevent moisture from accumulating and 
damaging the electronics. Use care when 
attaching/using/storing sensor, so that 
nothing blocks the vent.

Ensure that the optics (B) are not exposed 
to direct water and sunlight for extended 
periods of time. Because direct sun (UV 
light) can be destructive, sensor should be 
oriented so that optics face the ground 
(even when not in use). To maximize the life 
and performance of sensors, they should be removed from equipment and housed in a protective environment 
when not in use.

Load Configuration

Press the Application App from the home screen. This will take you through the steps needed to load a 
configuration.

Once a configuration has been completed, the Map View screen appears.

Map View

A.

Menu button

B.

Total Logged Field Area

C.

Ground Speed

D.

AgFiniti Status

E.

Diagnostics

F.

GPS Signal Indicator

G.

Display Legend

H.

Product Control toolbox

I.

Vehicle Icon

J.

Event Summary

K.

Map View

L.

Split screen

M.

AutoSwath

N.

Master Switch Status

O.

OptRx button

P.

Target Rate/Average VI

Q.

Bar Graph

R.

Reference Strip buttons

Legend

NH3

Flow:

Container:

67.5

875

Rate:

N

Reference Strip

Create

View All

OptRx

Target Rate

N

Average VI

Содержание OptRx

Страница 1: ...osed to direct water and sunlight for extended periods of time Because direct sun UV light can be destructive sensor should be oriented so that optics face the ground evenwhennotinuse Tomaximizethelif...

Страница 2: ...ual Rate Actual Rate The Flow Sensor returns the actual rate being applied NOTE In some conditions the Actual Rate may increment slower than the Target Rate or its numeric values may vary before match...

Страница 3: ...eir desired rates to apply any product to any crop type based on the vegetative index You can create up to 16 ranges and assign a desired rate to these ranges You also have the ability toselect your V...

Страница 4: ...r field for 300 seconds 5 minutes Wheat North America Tillering Scan the most vigorous portion of your field for 300 seconds 5 minutes Europe Scan the portion of your field where the plants show an av...

Страница 5: ...Barley the Growth Stage is used to select the most appropriate VI index NDVI or NDRE further it will be used for fine tuning and optimizing the N Algorithm Press when finished 3 Drive Reference Strip...

Страница 6: ...trip by pressing the View All button located on the bottom right hand side of the Map screen s Equipment Tab The file name of the new reference strip appears in the Reference Strip Selection screen To...

Страница 7: ...used to apply a minimum amount of N on ground with damaged crops You may enter in a value either by pressing or you may enter in the current VI value by pressing The minimum rate may be adjusted at t...

Страница 8: ...viewed and set for each application Algorithm implication The Minimum Rate is the amount of nitrogen the operator wants applied to the healthiest areas of a field Keep in mind OptRx may apply very low...

Страница 9: ...iewed and set for each application Algorithm implication The Pre Sidedress Rate is the amount of nitrogen that has been applied for the current year s crop before side dressing Keep in mind not all pr...

Страница 10: ...field average and that the Minimum and Maximum Rate have an equal offset from the Planned Rate The Planned Rate should be set to the intended flat rate to apply if the OptRx N Algorithm was not used M...

Страница 11: ...e exact values for these inputs are up to the grower ideally after consulting with an agronomist Ag Leader Technology does not provide agronomic advice Override Serial Logging Checking Logging Overrid...

Страница 12: ...row sensor placement Checklist Sensors should be equally spaced apart Sensors should not be mounted on the ends of the booms Each sensor should be mounted so that it is centered over the top of a crop...

Страница 13: ...mote sensing that displays a comparison of crop vigor and biomass of the scanned plant This value which is taken from a reference scan of a Reference Strip uses a ratio that indicates the health of th...

Страница 14: ...here has been a drop in voltage to the OptRx Crop Sensors Solution Check voltage on the high current power cable to ensure voltage provided to the sensors is approximately 12 V Error Message Too Few S...