background image

OptRx

11 

PN 2006020–ENG Rev. H

Number of Applications

—This input is dependent on your season planning; it should not be changed during the 

season. 

Algorithm implication: The Number of Applications reflects the total amount on N-applications throughout a season, 
including pre-seeding applications. A higher Number of Applications will decrease the algorithms aggressiveness, 
and the target rate will show less variation. 

Application Trend

—This input should be reviewed and set for each application.

 Algorithm implication: The Application Trend setting decides whether good crops get a higher N rate, or if poor 
crops get a higher N rate. The Increase setting trends the N application rate towards the healthier crops. This could 
result in witnessing greater plant variance within a field. The Decrease setting trends the N application rate towards 
the unhealthy crops. This could result in witnessing little plant variance within a field. 

÷

NOTE!: The exact values for these inputs are up to the grower, ideally after consulting with an agronomist. Ag Leader 
Technology does not provide agronomic advice.

Override Serial Logging

Checking Logging Override will allow OptRx to 
disable logging based on speed if a reference 
strip is loaded or an application rate table is 
being used. This checkbox will only be available 
when OptRx is configured with a non-Ag Leader 
product controller (Generic ISOBUS or Serial 
controller).

÷

NOTE!: If left unchecked in these types of 
configurations, the Event may not be able 
to be Suspended or Closed due to OptRx 
being in a logging state.

Sensor Setup

The crop Sensor Setup screen is where you can review and adjust sensor settings. You can access the Sensor Setup screen 
one of two ways:

OR

Crop Sensor

Sensor 

Configuration

Corn 

Settings

North America 

Wheat Settings

Europe 

Settings

Use Application 

Rate Table

Serial Number:

Firmware Version:

Hardware Revision:

Logging Override

Crop sensor technology designed by Holland Scientific, Inc.

Configuration

Select Your Specific 

Configuration

Crop Sensor

Settings

Configuration 

Settings

Crop Sensor

Sensor 

Configuration

Содержание OptRx

Страница 1: ...osed to direct water and sunlight for extended periods of time Because direct sun UV light can be destructive sensor should be oriented so that optics face the ground evenwhennotinuse Tomaximizethelif...

Страница 2: ...ual Rate Actual Rate The Flow Sensor returns the actual rate being applied NOTE In some conditions the Actual Rate may increment slower than the Target Rate or its numeric values may vary before match...

Страница 3: ...eir desired rates to apply any product to any crop type based on the vegetative index You can create up to 16 ranges and assign a desired rate to these ranges You also have the ability toselect your V...

Страница 4: ...r field for 300 seconds 5 minutes Wheat North America Tillering Scan the most vigorous portion of your field for 300 seconds 5 minutes Europe Scan the portion of your field where the plants show an av...

Страница 5: ...Barley the Growth Stage is used to select the most appropriate VI index NDVI or NDRE further it will be used for fine tuning and optimizing the N Algorithm Press when finished 3 Drive Reference Strip...

Страница 6: ...trip by pressing the View All button located on the bottom right hand side of the Map screen s Equipment Tab The file name of the new reference strip appears in the Reference Strip Selection screen To...

Страница 7: ...used to apply a minimum amount of N on ground with damaged crops You may enter in a value either by pressing or you may enter in the current VI value by pressing The minimum rate may be adjusted at t...

Страница 8: ...viewed and set for each application Algorithm implication The Minimum Rate is the amount of nitrogen the operator wants applied to the healthiest areas of a field Keep in mind OptRx may apply very low...

Страница 9: ...iewed and set for each application Algorithm implication The Pre Sidedress Rate is the amount of nitrogen that has been applied for the current year s crop before side dressing Keep in mind not all pr...

Страница 10: ...field average and that the Minimum and Maximum Rate have an equal offset from the Planned Rate The Planned Rate should be set to the intended flat rate to apply if the OptRx N Algorithm was not used M...

Страница 11: ...e exact values for these inputs are up to the grower ideally after consulting with an agronomist Ag Leader Technology does not provide agronomic advice Override Serial Logging Checking Logging Overrid...

Страница 12: ...row sensor placement Checklist Sensors should be equally spaced apart Sensors should not be mounted on the ends of the booms Each sensor should be mounted so that it is centered over the top of a crop...

Страница 13: ...mote sensing that displays a comparison of crop vigor and biomass of the scanned plant This value which is taken from a reference scan of a Reference Strip uses a ratio that indicates the health of th...

Страница 14: ...here has been a drop in voltage to the OptRx Crop Sensors Solution Check voltage on the high current power cable to ensure voltage provided to the sensors is approximately 12 V Error Message Too Few S...

Отзывы: