OptRx
11
PN 2006020–ENG Rev. H
Number of Applications
—This input is dependent on your season planning; it should not be changed during the
season.
Algorithm implication: The Number of Applications reflects the total amount on N-applications throughout a season,
including pre-seeding applications. A higher Number of Applications will decrease the algorithms aggressiveness,
and the target rate will show less variation.
Application Trend
—This input should be reviewed and set for each application.
Algorithm implication: The Application Trend setting decides whether good crops get a higher N rate, or if poor
crops get a higher N rate. The Increase setting trends the N application rate towards the healthier crops. This could
result in witnessing greater plant variance within a field. The Decrease setting trends the N application rate towards
the unhealthy crops. This could result in witnessing little plant variance within a field.
÷
NOTE!: The exact values for these inputs are up to the grower, ideally after consulting with an agronomist. Ag Leader
Technology does not provide agronomic advice.
Override Serial Logging
Checking Logging Override will allow OptRx to
disable logging based on speed if a reference
strip is loaded or an application rate table is
being used. This checkbox will only be available
when OptRx is configured with a non-Ag Leader
product controller (Generic ISOBUS or Serial
controller).
÷
NOTE!: If left unchecked in these types of
configurations, the Event may not be able
to be Suspended or Closed due to OptRx
being in a logging state.
Sensor Setup
The crop Sensor Setup screen is where you can review and adjust sensor settings. You can access the Sensor Setup screen
one of two ways:
OR
Crop Sensor
Sensor
Configuration
Corn
Settings
North America
Wheat Settings
Europe
Settings
Use Application
Rate Table
Serial Number:
Firmware Version:
Hardware Revision:
Logging Override
Crop sensor technology designed by Holland Scientific, Inc.
Configuration
Select Your Specific
Configuration
Crop Sensor
Settings
Configuration
Settings
Crop Sensor
Sensor
Configuration