background image

OptRx

PN 2006020–ENG Rev. H

Press the OptRx prescription button to engage the OptRx system to apply variable rate N, based on data 
received from the sensors. The OptRx button will not be selectable until a Reference Strip is made or Application 
Rate Table is in use.

Create Configuration

A wizard will guide you through the process of selecting or creating a configuration with application settings. 

The configuration can be started in two places:

OR

Your Operating Configuration will then be viewable when you start a new Field Operation with the Application Wizard.

÷

You can also use the 

Manage Equipment 

button to create or edit specific vehicles and implements.

Application Rate Table 

To use the Application Rate Table, you need to activate it by check marking the "Use Application Rate Table" box in the 
Crop Sensor setup. It can be accessed one of two ways:

OR

The Application Rate Table allows a user to 
define their desired rates to apply any product to 
any crop type, based on the vegetative index. 
You can create up to 16 ranges and assign a 
desired rate to these ranges. You also have the 
ability to select your VI type to NDRE or NDVI. (For 
more information about NDRE and NDVI, refer to 
the Glossary.) If you select to use the Application 
Rate Table you will not make a reference strip. 
You will set up the rate table and start applying. 
If you don’t select to use the Application Rate 
Table you will have to make a reference strip 
before you apply. The exact values for these 
settings are up to the grower, ideally after 
consulting with an agronomist. Ag Leader 
Technology does not provide agronomic advice.

÷

NOTE!: When utilizing the Application 
Rate Table, a minimum of two sensors are 
required in order to actively apply product.

Configuration

Application

Configuration

Select Your Specific 

Configuration

Crop Sensor

Use Application 
Rate Table

Settings

Configuration 

Settings

Crop Sensor

Use Application 
Rate Table

Crop Sensor Rate Table

Lower Bound

Upper Bound

Rate

Number of Ranges

VI Type

NDRE

Press on a value in the table to edit.

Содержание OptRx

Страница 1: ...osed to direct water and sunlight for extended periods of time Because direct sun UV light can be destructive sensor should be oriented so that optics face the ground evenwhennotinuse Tomaximizethelif...

Страница 2: ...ual Rate Actual Rate The Flow Sensor returns the actual rate being applied NOTE In some conditions the Actual Rate may increment slower than the Target Rate or its numeric values may vary before match...

Страница 3: ...eir desired rates to apply any product to any crop type based on the vegetative index You can create up to 16 ranges and assign a desired rate to these ranges You also have the ability toselect your V...

Страница 4: ...r field for 300 seconds 5 minutes Wheat North America Tillering Scan the most vigorous portion of your field for 300 seconds 5 minutes Europe Scan the portion of your field where the plants show an av...

Страница 5: ...Barley the Growth Stage is used to select the most appropriate VI index NDVI or NDRE further it will be used for fine tuning and optimizing the N Algorithm Press when finished 3 Drive Reference Strip...

Страница 6: ...trip by pressing the View All button located on the bottom right hand side of the Map screen s Equipment Tab The file name of the new reference strip appears in the Reference Strip Selection screen To...

Страница 7: ...used to apply a minimum amount of N on ground with damaged crops You may enter in a value either by pressing or you may enter in the current VI value by pressing The minimum rate may be adjusted at t...

Страница 8: ...viewed and set for each application Algorithm implication The Minimum Rate is the amount of nitrogen the operator wants applied to the healthiest areas of a field Keep in mind OptRx may apply very low...

Страница 9: ...iewed and set for each application Algorithm implication The Pre Sidedress Rate is the amount of nitrogen that has been applied for the current year s crop before side dressing Keep in mind not all pr...

Страница 10: ...field average and that the Minimum and Maximum Rate have an equal offset from the Planned Rate The Planned Rate should be set to the intended flat rate to apply if the OptRx N Algorithm was not used M...

Страница 11: ...e exact values for these inputs are up to the grower ideally after consulting with an agronomist Ag Leader Technology does not provide agronomic advice Override Serial Logging Checking Logging Overrid...

Страница 12: ...row sensor placement Checklist Sensors should be equally spaced apart Sensors should not be mounted on the ends of the booms Each sensor should be mounted so that it is centered over the top of a crop...

Страница 13: ...mote sensing that displays a comparison of crop vigor and biomass of the scanned plant This value which is taken from a reference scan of a Reference Strip uses a ratio that indicates the health of th...

Страница 14: ...here has been a drop in voltage to the OptRx Crop Sensors Solution Check voltage on the high current power cable to ensure voltage provided to the sensors is approximately 12 V Error Message Too Few S...

Отзывы: