0
Cam
Sense
Error
Piston took
more than 6
minutes to
advance
Unplug the system, disconnect the piston
from the motor/gear, and verify that the
piston moves freely inside the valve; if it
does not replacement of the seal and
spacers and possibly the piston is required.
After reconnecting the piston, inspect the
control head for any broken, worn, or
disconnected parts, and replace or
reconnect any that are found. Perform a
hard reset. After verifying programming
run the system through a regeneration and
watch the motor to ensure that it is
moving the piston, if it is not the motor
needs to be replaced. If error still occurs
contact us for support.
1
Cycle Step
Error
Unexpected
cycle input
Unplug the system and check to ensure all
electrical connections and cam switches
are secure. Plug the unit back in and check
the master programming and ensure valve
type and system type are correct for your
system. Initiate a manual regeneration
and verify it progresses through the steps
correctly. If error reoccurs, contact us for
support.
2
Regen
Failure
More than
99 days
since last
regeneration
(7 on day of
the week
setups)
Perform a manual regeneration to reset
the error. Check your settings to ensure the
system is setup to regeneration
automatically.
Check the meter to ensure
it is not stuck and that the gallons
remaining is counting down.
3
Memory
Error
Circuit board
memory
failure
Perform a hard reset and go through the
master programming to update the
settings. If error occurs again contact us
for support
27 of 28