Tc
Time Clock - will begin a regeneration
cycle at the set regeneration time after
the set number of days has passed.
Common setting on all backwashing
systems except water softeners to
ensure consistent cleaning of the media.
dAY
Day of the Week - will begin a
regeneration cycle on the set day(s) at
the set regeneration time. More
consistent Time Clock setting is
recommended in most situations.
NT
Number
of Tanks
1
For systems with only 1 media tank (all
systems except dual tank softeners).
2
For systems with 2 media tanks (dual
tank softeners only).
UT
Indicates
current
tank in
service
U1
Tank 1 is in service
U2
Tank 2 is in service (dual tank softeners
only).
C
Capacity -1-999.9
(x1000)-
System capacity, in grains. Metered
softeners only. This will be set to match
your system size, so a 48k or 48,000
grain system will be set to 48. Reference
the tank size chart above for help in
matching up your tank size with
capacity.
H
Hardness
-1-199-
Hardness of the water, in grains.
Metered softeners only. Hardness, this is
the hardness of the water as measured
in grains per gallon (GPG). If your test
shows hardness as parts per million
(ppm) or milligrams per liter (mg/l)
simply divide by 17.1 to get grains per
gallon.