RR
Rapid
Rinse
10
The rapid rinse cycle runs water through
the tank in the normal direction to rinse
off any excess salt and settle the resin
for normal operation. During this cycle
there will be a steady flow of water
down the drain.
BF
Brine Fill
12
This sets the length of the brine fill
portion of the cycle. During this cycle
the system will put water into the brine
tank.
-Please note:-
The brine tank will
have water in it after this cycle
completes and it will remain in the tank
until the next regeneration, this is
normal. Exact amount will vary, and
water level in the brine tank may be
above OR below the salt level depending
on system, brine tank, and amount of
salt in the tank.
D1-D7
Doy of
the Week
Setting
OFF
Set to On or OFF for each dayof the
week. Only applies to systems with
Control Type dAY, not typically used.
CD
Current
Day
1-7
Used to set the current day. Only applies
to systems with Control Type dAY, not
typically used.
FM
Flow
Meter
Type
-P0.7-
3/4" Paddle Wheel Meter For the larger
domed meter used on most softeners.
Gen
Generic or Other Meter
P2.0
2" Paddle Wheel Meter
t1.5
1.5" Turbine Meter
P1.5
1.5" Paddle Wheel Meter
t1.2
1.2" Turbine Meter
t1.0
1" Turbine Meter
P1.0
1" Paddle Wheel Meter
17 of 28