![AFRISO SonarFox UST 20 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/afriso/sonarfox-ust-20/sonarfox-ust-20_operating-instructions-manual_2864831022.webp)
SonarFox UST 20
AFRISO
22
CLONE SETTINGS
This operating mode is for copying the configuration of the level meter
(body) UST 20 into the display module (Display) PD 20 UST/PMG and
back. The display module can then be removed from the level meter
body and put into another level meter and make there the settings
transfer (cloning).
The "CLONE SETTINGS" mode transfers all data, excluding setting of
the "Teaching" and HART®.
BASIC SETTINGS
SERVICE
DIAGNOSTIC
CLONE SETTINGS
PASSWORD
LANGUAGE
INFO
CLONE SETTINGS
SENSOR MODULE
DISPLAYS
MODULE SENSOR
DISPLAYS
CLONE SETTINGS
SENSOR MODULE
DISPLAYS
MODULE SENSOR
DISPLAYS
CLONE SETTINGS
NOW CLONING
1.
Press the OK button to open the “CLONING SETTINGS” menu.
Copying of the settings is done by selecting "SENSOR → DISPLAY MODULE". To transfer the
settings from the display module to another level meter select the item DISPLAY MODULE →
SENSOR.
2. Use the arrow buttons to select the operating mode and press OK.
-
During transmission the display shows "NOW CLONING".
-
After completing the process in the middle of the screen displays "DONE“.
3.
Press the ESC button to exit the menu:
CLONE SETTINGS
!WARNING!
CLONING NOT POSSIBLE
WRONG SENSOR TYPE
PRESS TO EXIT ESC
Incompatible type. Transfer of the settings can be realized only
with the same type of level meter and with the firmware version
2.0 and later.
CLONE SETTINGS
!WARNING!
CLONING NOT POSSIBLE
NO SETTINGS SAVED
PRESS TO EXIT ESC
The data set is not stored into the display module (DM–70). The
transfer can not be done. It is necessary to repeat the procedure
of the copying the settings in the mode "CLONE SETTINGS".
PASSWORD
Here the product can be blocked against unauthorized data processing. Once the password has
been activated, the data can be viewed, but not edited. If you try to edit, the message "NO PASS
-
WORD ENTERED" appears on the display.
The password can consist of any 5-digit numeric combination. The combination 00000 is reserved
for deactivating the password.
1. Press the OK button to open the "PASSWORD" menu.
2.
Use the arrow buttons to select the the operating mode for entering the password “ENTER” or
changing the password “CHANGE” and press OK.
- When activated, both messages appear inversely.
3.
Press the OK button again to confirm the selection.
- The password change is only possible when the level meter is unlocked. Otherwise the
message "NO PASSWORD ENTERED" appears.
4.
Enter the Password.
- The current entry for editing is shown inversely.
Содержание SonarFox UST 20
Страница 2: ...SonarFox UST 20 AFRISO 2 ...
Страница 34: ...SonarFox UST 20 AFRISO 34 20 EU Declaration of Conformity ...
Страница 35: ...35 AFRISO SonarFox UST 20 ...
Страница 36: ...SonarFox UST 20 AFRISO 36 21 EU Type Examination Certificate ...
Страница 37: ...37 AFRISO SonarFox UST 20 ...
Страница 38: ...SonarFox UST 20 AFRISO 38 ...