13
Product description
EN
RF ... EX / KP ... EX / PF ... EX
4.3
Technical specifications
See the current AFRISO catalogue or www.afriso.com for additional technical
specifications such as product dimensions and installation dimensions.
4.3.1
Bourdon tube pressure gauges
Parameter
Value
General specifications
Measuring ranges
-1/0 bar to -1/15 bar
0/0.6 bar to 0/1600 bar
Temperature performance
Rising temperature approx. +0.04 %/K
Falling temperature approx. -0.04 %/K
(indication error when the temperature
of the measuring system deviates from
the normal temperature of +20 °C, with
reference to the full scale value)
Operating frequency in hazardous
areas (EX areas)
Max. 0.1 Hz
Operating temperature range
Ambient
-20/+60 °C
Medium
Max. +60 °C for liquid filled devices and
devices with soft-soldered Bourdon
tubes
Max. +80 °C for non-filled devices with
hard-soldered or welded bourdon tube
Storage
-40/+70 °C
Application range with static load
Up to full scale value
Type: D4, D8
In NG 100, NG 160
(cl. 1.0 to < 600 bar)
Up to 3/4 full scale value
Type: D7, D9
Type: D4, D8
Type: D4
All nominal sizes
In NG 50, NG 63
In NG 160 (cl. 0.6 cl. 0.25 cl. 0.1 and cl.
1.0 > 600 bar)
Содержание KP EX Series
Страница 41: ...41 Anhang DE RF EX KP EX PF EX 16 Anhang 16 1 Zulassungsunterlagen ...
Страница 42: ...42 Anhang DE RF EX KP EX PF EX 16 2 EU Konformitätserklärung ...
Страница 43: ...43 Anhang DE RF EX KP EX PF EX ...
Страница 44: ...44 Anhang DE RF EX KP EX PF EX 16 3 Informationen zur Druckgeräterichtlinie ...
Страница 84: ...40 Appendix EN RF EX KP EX PF EX 16 Appendix 16 1 Approval documents ...
Страница 85: ...41 Appendix EN RF EX KP EX PF EX 16 2 EU Declaration of Conformity ...
Страница 86: ...42 Appendix EN RF EX KP EX PF EX ...
Страница 87: ...43 Appendix EN RF EX KP EX PF EX 16 3 Information on the Pressure Equipment Directive ...