Technical data
14
LAG-14 ER
4 Technical data
Table 1: Technical specifications probe and container
Parameter
Value
General specifications
Dimensions tank
(W x H x D)
300 x 325 x 145 mm
Space requirements
(W x H x D)
500 x 700 x 200 mm
Weight
1.0 kg
Electrode housing
Plastic, Ø 34 mm
Electrode rods
V 2 A, Ø 3 mm
Resistance
Leak detection fluid
Connection cable:
Standard length
Max. length
H05VV-F, 2 x 1 mm²
1 m
50 m (shielded)
Container (conductive)
black
Hostalen / Vestolen
Surface resistance
< 10
9
Ohm as per DIN 53486
Active volume
4.5 litres
(electrode tip to liquid level)
Total volume
10 litres
Connecting hose
EPDM hose 14 x 3 (ID 14)
Operating temperature range
Ambient
-25 °C to +50 °C, depending
on mixing ratio
Storage
-25 °C to +60 °C, depending
on mixing ratio
Supply voltage
Probe voltage
Max. 17 V, AC
Electrical safety
Degree of protection
IP 20 (EN 60529)