16
◆
Use crimping pliers to fasten the meatal connecting tube and copper wire. Make sure the harness will
not fall off, see picture below.
◆
Insert the assembled cable into male/ female connector. A “chick” sound can be heard when
connecting correctly. Then tighten the cap. Refer to the picture below.
5.3.3 Connecting the PV Generator (DC)
DANGER!
Danger to life due to high voltage in the inverter.
• Before connecting the PV generator, ensure that the AC&DC circuit breaker is switched off.
Notes:
1. Make sure that you have disconnected circuit breakers and switches on both DC and AC sides.
2. Check the connection cables of the PV modules for correct polarity and that the maximum input voltage
of the inverter is not exceeded.
3. Check the DC plug connector for correct polarity and well connected.