14
5.3.1 Conditions for the DC Connection
• The connected PV modules must meet following requirements
– Same type
– Same model
– Identical alignment
– Identical tilt
• The following limit values at the DC input of the inverter must not be exceeded (connecting to a higher
voltage will destroy the device):
Type
Maximum input voltage [Vd.c]
Maximum input current [Ad.c]
Anyhome Series(Single MPPT tracker)
HNS1000TL-1
450
10
HNS1500TL-1
450
10
HNS2000TL-1
500
12
HNS2500TL-1
500
14
HNS3000TL-1
500
17
HNS3600TL-1
550
17
Anyhome Series(Double MPPT trackers)
HNS3000TL
550
12 x2
HNS3600TL
550
15 x2
HNS4000TL
550
16 x2
HNS5000TL
550
18 x2
HNS6000TL
550
18 x2
HNS7000TL
550
18 x2
HNS8000TL
550
18 x2
5.3.2 Assembling the DC Plug Connector
In order to connect to the inverter, all connection cables of the PV modules must be equipped with the DC
plug connectors provided. You will find the necessary DC plug connector for DC connection in the package.
To assemble the DC plug connectors, proceed as detailed below. Ensure the plug connectors have the
correct polarity.
The plug connector in DC side includes male and female as blow.