25
Clr ErrRcd
Fault Clearing
Clr AllRcd
All data clearing
To set time and country,please refer to fist boot setting in 8.1.4.1. Press Esc when finishing.
Passwords are needed for the other items setting, which only can be operated by after sales to make sure
the safety and normal operation of the inverter.
7.2 LCD Backlight Control
The backlight of LCD will automatically turn off after 5 minutes, and LCD will automatically turn off after
10 minutes to electricity-saving mode. Press any key to turn on the LCD.
8 Technical Data
PV modules connecting to inverter should comply with the requirement of IEC61730 class A, and PV arrays
are not earthed.
Anyhome Series(Single MPPT Tracker)
Electrical Specifications
HNS1000TL-1 HNS1500TL-1 HNS2000TL-1 HNS2500TL-1 HNS3000TL-1 HNS3600TL-1
Input (DC)
Max DC Power (W)
1200
1800
2400
3000
3600
3600
Max DC Voltage (V)
500
500
550
500
500
550
Rated/Recommended Voltage
(V)
360
360
360
360
360
380
MPPT DC Voltage Range (V)
50-400
90-400
120-400
120-400
120-400
120-450
Start up DC Voltage (V)
60
60
150
150
150
150
Turn off DC Voltage (V)
45
45
120
120
120
120
Max DC Current (A)
10
10
12
14
17
17
Isc PV (A)
12.5
12.5
15
17.5
21
21
Number of MPPT Tracker
1
1
1
1
1
1
Number of DC connections
(set)
1
1
1
1
1
1
Max Backfeed Current (mA)
<
1
<
1
<
1
<
1
<
1
<
1
Output (AC)
Power Connector
Single Phase Three Wire
Max AC Power (W)
1050
1550
2100
2600
3100
3700
Nominal AC Power (W)
1000
1500
2000
2500
3000
3600
Max.AC Current (A)
6
9
12
13
15
18
Nominal AC Current (A)
6
8
10
12
13
16
Max AC Inrush Current (A)
6
8
10
12
13
16
Max AC Fault Current (A)
9
12
15
18
19.5
24
Max AC Protect Current (A)
9
12
15
18
19.5
24