20
There are four function keys on the front panel: UP, DOWN, ESC, ENT. The keypad is used for:
Up and Down keys: Scrolling the displayed parameter , or modify the adjustable parameters
Esc and Ent keys: Cancel or Enter.
7.2 Commissioning
After completing of the mechanical and electrical installation, the inverter could be put into operation.
1.
Switch off DC and AC side circuit breakers and switches.
2.
Wait until the screen is on and set up grid connection standard. (Please refer to 7.1.4 for specific
operations)
The inverter starts up and feed into the utility grid automatically when all the necessary conditions of
normal operation for the inverter is fulfilled.
3.
Check whether the display and LEDs are indicating a normal operating state.
Sign
Color
Instructions
POWER
Green
On: Power On
RUN
Green
On: Normal Operation and feed into the utility grid
GRID
Green
Shine: Normally generate electricity
FAULT
Red
Flash: Check wiring
7.3 LED Display
Three LED lights are assembled on the inverter, COM, POWER, FAULT. When DC and AC power are normal
and the inverter starts up, the POWER LED turns on. When the inverter is operating and feed electricity into
the utility grid normally, the COM LED turns on. When there is faulty in the PV system or inverter, the FAULT
LED flashes, and the faulty code will be shown on LCD screen.
POWER LED (Green)
POWER LED turns on when DC voltage reaches the start-up voltage and turns off when it falls below a
certain value. POWER LED is on represents inverter is active and so is the inverter control system. If POWER
LED is off, inverter cannot be normally started up.
Under normal operation conditions, when sun light is sufficient, inverter start up generates electricity in the
morning and stops after dark. This procedure may repeat several times in one day, especially in morning
and at night. It is a normal working phenomenon but not a wrong signal.
COM LED (Green)
Содержание Anybuild Series
Страница 1: ...USER S MANUAL On Grid PV Inverter Anybuild Series BNT050KTL BNT060KTL Version 03 610100050005 V0 01 ...
Страница 2: ......
Страница 14: ...13 6 Joint the wires with screws and tighten the screws 7 Cover the lid and tighten screws ...
Страница 38: ......
Страница 39: ......