2.Machine failure
automatically
restart.
2.Please contact with local dealer if error remains the same
after several reset.
GFCI.Err
1.PV(+) or PV(-) earthing
2.Machine failure
1.Check
PV(+)
and
PV(-)
ground impedance,
make
sure impedance is more than 2M
Ω
.
2.Please contact with local dealer if error remains the same
after several reset.
GridF.OutLim
Electricity grid fluctuations
Electricity grid Frequency out of
range
Machine failure
1.After
elec
tricity
grid returns to normal,
the mac
hine will
automatically restart.
2.Please contact with local dealer if error remains the same
after several reset.
GridV.OutLim
Off Phase
2.Electricity
grid
Phase/line
voltage overload
3.electricity
grid
Voltage
unbalance
1.Disconnect the input/output switch, check the AC-side wiring
and reseat the plug to rule out bad contact.
2.After electricity grid returns to normal, the mac
hine will
automatically restart.
3.Please contact with local dealer if error remains the same
after several reset.
IntFaultA
Machine failure
Please contact with local dealer if error remains the same after
several reset.
IntFaultB
1.PV input voltage is too high
2.Electricity grid abnormal
3.Bus hardware overvoltage fault
1.Adjust the panel configuration to lower the input voltage.
2.After electricity grid returns to normal, the mac
hine will
automatically restart.
3.Please contact with local dealer if error remains the same
after several reset.
IntFaultC
Electricity grid abnormal
Unbalanced current fault
1.After electricity grid returns to normal, the machine will
auto
matically restart.
2.Please contact with local dealer if error remains the same
after several reset.
IntFaultD
1.Electricity grid abnormal
2.Software over current fault
1.After electricity grid returns to normal, the machine will
automatically resta
rt.
2.Please contact with local dealer if error remains the same
after several reset.
IntFaultE
1.Electricity grid abnormal
2.Hardware over current fault
1.After electricity grid returns to normal, the mac
hine will
automatically restart.
2.Please contact with local dealer if error remains the same
after several reset.
IntFaultG
1.Electricity grid abnormal
2.DCI too high
1.After electricity grid returns to normal, the mac
hine will
automatically restart.
2.Please contact with local dealer if error remains the same
after several reset.
IntFaultJ
Relay failure
Please contact with local dealer if error remains the same after
several reset.
IntFaultK
1.Electricity grid abnormal
2.Bus differential fault
1.After electricity grid returns to normal, the mac
hine will
automatically restart.
2.Please contact with local dealer if error remains the same
after several reset.
IntFaultL
1.Electricity grid abnormal
1.After electricity grid returns to normal, the machine
will