Originale Instructions- Rev.1.3
User Maunal– Loreena
46/ 68
6.
Electrical/Environmental Requirements
6.1.
Electrical (Supply Voltage Fluctuations Not to Exceed
+/- 10%)
AFI-C300V
115V
60Hz 9 Amp
1 Phase
UL/UL-C Listed
AFI-C300R
115V
60Hz 17 Amp
1 Phase
UL/UL-C Listed
AFI-C300V-E
230V
50Hz 4 Amp
1 Phase
CE Certified
AFI-C300R-E
230V
50Hz 8 Amp
1 Phase
CE Certified
AFI-C300RF
115V
60Hz 17 Amp
1 Phase
CE Certified
AFI-C300RF-E
230V
50Hz 8 Amp
1 Phase
CE Certified
6.2.
Operational Performance (for indoor use only)
Environment Temperature Range: 60⁰F - 85⁰F (15⁰C - 30⁰C)
Environment Humidity: Maximum relative humidity 80% for temperatures up to 31⁰C decreasing linearly to
50% relative humidity at 40⁰C
Environment Altitude: 6562 Feet (2000 meters) above sea level
6.3.
Light Exposure
Standard Fluorescent Lighting @ 150 ft. candles (1614 LUX) maximum intensity.
6.4.
Installation Category: 2.0
Installation category (overvoltage category) defines the level of transient overvoltage, which the instrument is designed
to withstand safely. It depends on the nature of the electricity supply and its overvoltage protection means. For
example, in CAT II, which is the category used for instruments in installations supplied from a supply comparable to
public mains such as hospital and research laboratories and most industrial laboratories, the expected transient
overvoltage is 2500 V for a 230 V supply and 1500 V for a 120 V supply.
6.5.
Pollution Degree: 2.0
Pollution degree describes the amount of conductive pollution present in the operating environment. Pollution degree
2 assumes that normally only non-conductive pollution such as dust occurs with the exception of occasional
conductivity caused by condensation.
6.6.
Chemical Exposure
Chemical exposure should be limited to antibacterial materials used for cleaning and disinfecting.
CHLORINATED AND HALOGEN MATERIALS ARE NOT RECOMMENDED FOR USE ON STAINLESS STEEL SURFACES.
6.7.
EMC Performance (classified for light industrial)
Emissions:
EN61326
Immunity:
EN61326
Class A equipment is intended for use in an industrial environment.
In the documentation for the user, a statement shall be included drawing
attention to the fact
that there may be potential difficulties in ensuring
electromagnetic compatibility in other environments, due to conducted as
well as radiated disturbances.
WARNING
Содержание AFI-C300R
Страница 1: ...User Manual Revision 1 3 English Version...
Страница 63: ...Originale Instructions Rev 1 3 User Maunal Loreena 61 68 Angular rotor NU RA24 2...
Страница 69: ...Originale Instructions Rev 1 3 User Maunal Loreena 67 68 10 EC Conformity Declaration...
Страница 70: ...Originale Instructions Rev 1 3 User Maunal Loreena 68 68 Blank page...
Страница 71: ......