AES uScope Manual

 

 

www.AESwave.com

        Copyright 2011 by Automotive Electronics Services, Inc.

 

Page 10 

 

 

Press and hold “OK” button until prompt changes to the next numerical file 
number - located in top right of screen. 

 

Press “OK” to exit the menu 

 
Save to USER file

 

 

Highlight “Save to user file” 

 

Use LEFT/RIGHT to select file number to save. Note: filename at top right of 
screen. 

 

Press and hold 

“OK” button until prompt at the top right of screen changes the file 

number.  

 

Press 

“OK” to exit the menu 

 

“CR” 

 

Cursor Values

 

 

Highlight the 

“CR” menu using the UP/DOWN arrow keys and press “OK” 

 

Use UP/DOWN to Highlight the desired cursor (Cursor V1, V2, T1 T2)  

 

Use LEFT/RIGHT to adjust cursor location. (Note:  The cursor values are located 
on the bottom left of the screen) 

 

To turn cursors off.   

o

 

Highlight either V1-V2 (vertical cursors) or T1-T2 (time cursors).   

o

 

Use LEFT/RIGHT to toggle between ON/OFF. 

 

Press “OK” to exit menu 

 

“ME”

   

Measurements 

Highlight the “ME” menu and press “OK” to activate the measurements value. 

 

To turn off measurement values. 

Use UP/DOWN and select “Enable On/OFF” 

 

Use LEFT/RIGHT to toggle between ON/OFF 

 

Press “OK” to exit menu 

 

“OP”

   

Options 

Highlight 

the “OP” and press “OK” to activate the menu. 

 

Probe Cal

 (Probe Calibration) 

 

Highlight Probe Cal 

 

At the top right of the screen, the uScope will specify what attenuation setting you 
are currently on (Note: 10x does not change anything within the scope other than 
the voltage settings will be 10x larger 

– 1volt per division will read 10 volt per 

division.  

 

Use the LEFT/RIGHT to pick the desired attenuation. 

 

Press 

“OK” to exit the menu 

Sample Speed 

 

Use LEFT/RIGHT to toggle between Normal screen update and PEAK to PEAK 
mode. (Peak to Peak mode is started by default.) 

 

Press “OK” to exit the menu 

Grid Intensity 

 

Use LEFT/RIGHT to adjust the brightness of the graticule lines. 

 

Press “OK” to exit the menu 

SigGen Freq (Connect leads to the frequency generator for this option)

 

 

This refers to the built in Frequency generator 

 

Use Left/Right to select the Frequency  

 

Press “OK” to exit the menu 
 

SigGen Duty (Connect leads to the frequency generator for this option)

 

 

This refers to the built in Frequency generator duty 

 

Use Left/Right to select the Frequency percentage 

Содержание uScope

Страница 1: ...for the student that is ready to start scope n The uScope is powered by an easy to use interface enhanced with automotive presets and reference waveforms Put the power of the uScope in your hand and shirt pocket Secondary ignition injectors mass air flow crank cam TPS 02 CTS you name it it ll scope it The uScope is also perfect for your low amp probe secondary ignition pickup and pressure transduc...

Страница 2: ...ll short o Always connect your test lead to the uScope before connecting to a circuit o Always disconnect from the circuit before disconnecting from the uScope Circuit Testing while Charging uScope It is not recommended to connect the uScope input channel to a circuit while the uScope is charging Doing so may result in a ground loop that can destroy equipment and possibly endanger the user Intende...

Страница 3: ...gnal generator DO NOT USE THIS PORT WHEN TESTING AN AUTOMOTIVE CIRCUIT USB to PC Connection and Charging Port The USB connector is a standard micro USB and is located in the middle left side of unit This port is used for PC and uScope communication and for charging the uScope Memory Card microSD Card The uScope incorporates a microSD memory card The card port is located in the center of the bottom...

Страница 4: ... Button Located on the right Press and hold B while in grid value mode and in measurement menu ME to save an image of the screen Arrows Navigation located on right side of the front face When the Main Menu is visible o Up and down arrows move between main menu and menu items o Left and right arrows make adjustments selections for the currently highlighted menu item OK Select menu Items OK menu Whe...

Страница 5: ...hlight Auto Setup and press hold OK to activate it Waveform Capture not using a PreSet 1 Turn on the uScope by sliding the switch located on the top right of unit to the right 2 Use the UP DOWN arrow keys and highlight the Tr Trigger menu item 3 Press OK and the menu will open 4 Use the UP DOWN arrow keys to highlight the Tr Mode Trigger Display Mode Menu item 5 Use the LEFT RIGHT arrow keys to se...

Страница 6: ...the Tr Level Trigger voltage level Menu item e Use the LEFT RIGHT arrow keys to set the trigger level The LEFT arrow key moves the trigger level down and the RIGHT key moves the trigger level up Note the Yellow dotted horizontall line in the display indicating the selected level f Note When Tr level menu item is selected The numerical value of the Trigger will be displayed on the top right of the ...

Страница 7: ...vices Inc Page 7 Switching between MENU and Grid Values To switch between GRID VALUES and the MAIN MENU press and hold the A button for approximaely 5 seconds Please note Tapping the A button for less than 5 seconds will hold the signal Display with Grid Values Display with Menu ...

Страница 8: ... screen will indicate if invert is on or off o The following will be displayed at the button right of the screen if invert is on INV Press OK when complete to close menu Ref Vert Pos Reference Vertical Position Highlight Ref Vert Pos Use the LEFT RIGHT to pick the desired position of the reference waveform Press OK to exit the menu T Time and Horizontal Setting Menu Highlight the T and press OK to...

Страница 9: ...zontal cursors Press OK to exit menu Tr HPos Trigger Horizontal Position Highlight HPos Use LEFT RIGHT to select the trigger horizontal position Press OK to exit menu PS Automotive Presets Menu memory card must be inserted Select the PS menu item and press OK to activate the menu Use UP DOWN to select preset type Use LEFT RIGHT to scroll through different preset setups Press and hold OK to load se...

Страница 10: ...ff measurement values Use UP DOWN and select Enable On OFF Use LEFT RIGHT to toggle between ON OFF Press OK to exit menu OP Options Highlight the OP and press OK to activate the menu Probe Cal Probe Calibration Highlight Probe Cal At the top right of the screen the uScope will specify what attenuation setting you are currently on Note 10x does not change anything within the scope other than the vo...

Страница 11: ...tup See below Press OK to exit menu Set Custom Startup Set current settings as default Highlight Set Customer Startup using UP DOWN Press and hold OK Message will appear on the upper right confirming the save Save ok Press OK to exit menu Reset Factory Default To reset your uScope to factory default settings Use UP DOWN to select Reset Factory Default Press and hold OK You will see a message flash...

Страница 12: ... Capture a Waveform onto a PC Turn the uScope On Plug the uScope into an available USB port on a computer Note The waveforms and presets are saved onto the uScope memory card Never remove the memory card doing so will interrupt some of the uScopes functions The uScope memory card will act as removable mass storage once plugged into your pc The folder can be accessed through my computer under Devic...

Отзывы: