- 11 -

5. OPERATING  THE  UNIT

This is achieved via the Digital Controller.

NEVER LET THE DIGITAL CONTROLLER GET WET. THIS MAY CAUSE AN ELECTRIC SHOCK OR FIRE. 

NEVER PRESS THE BUTTONS OF THE DIGITAL CONTROLLER WITH A HARD, POINTED OBJECT. THIS MAY 
DAMAGE THE DIGITAL CONTROLLER.  

NEVER INSPECT OR SERVICE THE DIGITAL CONTROLLER YOURSELF. REFER TO A QUALIFIED SERVICE 
ENGINEER. 

Features and functions 

Basic controller functions

 

The basic controller functions are: 

Turning the heat pump ‘ON’/’OFF’.

24 hour time clock.

Timer ‘ON’ and Timer ‘OFF’.

Parameter adjustment.

Automated Environmental Systems Ltd., Unit B, Anglian Lane, Bury St Edmunds, Suffolk IP32 6SR

01842 819130 | [email protected] 

Содержание Remora Professional 10

Страница 1: ...T PUMP MANUAL Remora Professional Inverter Swimming Pool Heat Pump Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 2: ......

Страница 3: ...ON 14 6 5 SETTING THE TIMER 15 6 6 PARAMTER SETTING 16 6 7 RUNNING STATUS QUERY 18 6 8 CHECK POWER CONSUMPTION 21 6 9 FAULT HISTORY 21 6 10 VACATION SETTING 22 6 11 TIMER SET FOR SILENT MODE 23 6 12 HELP 23 7 ERROR CODES 24 8 MAINTENANCE AND INSPECTION 28 9 WIRING DIAGRAMS 34 10 CABLE SPECIFICATION 36 READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT DO NOT THROW IT AWAY RETAIN FOR FUTURE REFER...

Страница 4: ... manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant For split type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has following characteristics a Durable The heat exchanger is made of PVC...

Страница 5: ...iance shall be installed in accordance with national wiring regulations Before obtaining access to terminals all supply circuits must be disconnected Spaces where refrigerant pipes shall be compliance with national gas regulations Servicing shall be performed only as recommended by the manufacturer The appliance shall be stored in a well ventilated area All working procedure that affets safety mea...

Страница 6: ...r the use of harmful substances in electric and electronic devices 4 The unit CANNOT be installed near the flammable gas Once there is any leakage of the gas fire can occur 5 Make sure that there is circuit breaker for the unit lack of circuit breaker can lead to electrical shock or fire 6 The heat pump is equipped with an over load protection system It does not allow for the unit to start for at ...

Страница 7: ...ng items are found inside the box Carton Box Item Image Quantity Swimming pool heat pump 1 Operation and Installation Manual 1 Accessories 1 Set Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 8: ...10 Remora Professional 14 Remora Professional 19 Remora Professional 25 A 653 715 B 870 1020 C 380 408 D 351 367 E 96 87 F 325 395 Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 9: ...fessional 35 A 1170 F 148 B 1389 G 875 C 409 H 1170 D 427 I 97 E 451 J 560 Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 10: ...ce only Please check the water inlet outlet label on the heat pump while plumbing installation The controller could be mounted on the wall 4 2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are presented 1 Fresh Air 2 Electricity 3 Pool filter piping The unit may be installed virtually anywhere outdoors For indoor pool...

Страница 11: ... no residual heat or flame Temperatures The unit does not need copper heat sink piping PVC pipe can be run straight into the unit Location Connect the unit in the pool pump discharge return line downstream of all filter and pool pumps and upstream of any chlorinators ozonators or chemical pumps Standard model have fittings which accept 32mm or 50 mm PVC pipe for connection to the pool or spa filtr...

Страница 12: ...y to or from the pool water Grounding the unit is still required to protect you against short circuits inside the unit 4 6 Initial startup of the Unit NOTE In order for the unit to heat the pool or spa the filter pump must be running to circulate water through the heat exchanger Start up Procedure After installation is completed you should follow these steps 1 Turn on your filter pump Check for wa...

Страница 13: ...AGE THE DIGITAL CONTROLLER NEVER INSPECT OR SERVICE THE DIGITAL CONTROLLER YOURSELF REFER TO A QUALIFIED SERVICE ENGINEER Features and functions Basic controller functions The basic controller functions are Turning the heat pump ON OFF 24 hour time clock Timer ON and Timer OFF Parameter adjustment Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130...

Страница 14: ...his Timer Set Timer This icon will show if set the Timer successfully and it will show in Grey if there is none Timer set Vacation mode This icon will show when the Vacation Mode Settings are valid Key tone ON 0FF This icon will show if turn key tone off by operating this button in 2nd page WiFi connection This icon will show if WiFi connection is activated and it will show in Grey if WiFi connect...

Страница 15: ... show outlet water temperature Keypad lock It indicates the kepad is locked press it to unlock the keypad ON OFF Turn Unit ON or OFF Setting Press this button to enter into Function Menu which includes Status Query Parameter Setting Vacation Setting Run Log WIFI Reset Historical Fault Help Status Check unit running status Energy Check power consumption Fault History Check what failures have happen...

Страница 16: ...ess the place at to enter into main running mode selection and set target water temperature 6 4 Sub running Mode Selection Press the place at to choose Main Running Modes and set Target Water Temperatures Press OK to confirm Press to enter Into Sub running Mode Selection Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironment...

Страница 17: ...nterface Press to enter into Timer setting interface Activate or Deactivate each Timer settings from the right sliding block Activated in BLUE and Deactivate in GREY Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 18: ... to enter into Parameter Settings Input Password 223344 to enter to set Parameter values Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 19: ...pump P1P5 mode 2 0 1 2 P4 Water pump running time in standby mode 2 1 30 P5 Water pump stopping time in standby mode 180 3 240 P6 TA temp display deviation 0 3 3 P7 Cool mode valid or not 1 0 1 P8 Electric heater H1 valid or not 0 0 1 Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 20: ...tus Query Press to enter into status query Press to navigate different pages Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 21: ...alue 10 TJ2 EVI PHE inlet temp Actual value 11 TH compressor suction gas temp Actual value 12 TA inlet water temp Actual value 13 TB outlet water temp Actual value 14 Inverter module temp Actual value 15 Required capacity Actual value 16 Actual operating capacity after revision Actual value 17 Inverter compressor current Actual value 18 Voltage Actual value 19 Model 20 4 way valve status ON OFF Au...

Страница 22: ...heater H1 ON OFF 26 High pressure switch ON OFF 27 Low pressure switch ON OFF 28 Flow switch FS ON OFF 29 External control Pump signal status ON OFF 30 External control signal status ON OFF 31 LCD Software version Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 23: ... and to navigate different pages Press on the screen to find out running time and how much electricity consumption kW h in every mode Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 24: ...ress the line under Start Time Press the line under End Time HERE turn ON or OFF the Vacation Setting on the screen below Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 25: ...de 6 12 Help Press on the screen Press and to navigate different pages Press on the screen Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 26: ...V2 T3 coil temp sensor outdoor PCB E06 Inverter compressor current protection System shutdown fault reported Check inverter compressor check outdoor PCB module E07 T4 ambient temp sensor failure System shutdown fault reported Check ambient temp sensor and outdoor PCB E08 T3 coil temp sensor failure System shutdown fault reported Check T3 coil temp sensor and outdoor PCB E09 TP exhaust gas temp sen...

Страница 27: ...tant power failure System shutdown fault reported Check drive board E22 TJ2 economizer inlet sensor failure System shutdown fault reported Check TJ2 inlet temp sensor and outdoor PCB E23 TJ economizer oulet sensor failure System shutdown fault reported Check TJ outlet temp sensor and outdoor PCB E24 TA inlet water temp sensor failure System shutdown fault reported Check TA inlet water temp sensor ...

Страница 28: ...tion System shutdown fault reported Check inverter compressor and outdoor PCB module board E35 Out of step System shutdown fault reported Check the drive board and compressor E36 Compressor phase loss System shutdown fault reported Check the drive board compressor and connection line E37 Compressor startup failure System shutdown fault reported Check the drive board and compressor E38 The evaporat...

Страница 29: ...03 Tp exhaust gas temp limiting frequency Normal protection X04 Compressor current limiting frequency Normal protection X05 IPM temp limiting frequency Normal protection Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 30: ...to minimise the risk of a flammable gas or vapour being present while the work is being performed General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall be sectioned off Ensure that the conditions within the area have been made safe by contr...

Страница 31: ...chinery and outlets are operating adequately and are not obstructed c Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected d Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of m...

Страница 32: ...ce loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall be at the correct rating Replace components only with parts specified by the manufacturer Other parts may result ...

Страница 33: ... is followed since flammability is a consideration The following procedure shall be adhered to Remove refrigerant Purge the circuit with inert gas Evacuate Purge again with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushed with OFN to render the unit safe This process may need to be repeated se...

Страница 34: ...components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant Waste Transfer Note arranged Do not mix refrigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be removed ensure tha...

Страница 35: ...refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrigerant c...

Страница 36: ...mora Professional 14 Remora Professional 19 Remora Professional 25 VSP VCC DC310 FG DC CN6 K1 K2 K3 K4 CN1 CN7 CN2 CN3 A B GND 12V RED BLU RED BLU CN5 CN15 4 RED BLK BLK BRO RED BLK GRN YLW Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Страница 37: ...PM board PE VSP VCC DC310 FG DC FAN2 5 VSP VCC DC310 FG DC FAN1 5 CN6 CN1 CN7 Inlet water temp CN9 CN8 Outlet water temp CN5 CN3 CN4 4 AC L2 AC N2 Y G B A GND 5V RED BLU BLU RED Low Pressure Switch CN40 4 NOTE The dotted line above is only applicable to the model with chassis electric heating belt other models are not applicable 2 BRO BLK BLU 4 BLK for 33KW Automated Environmental Systems Ltd Unit...

Страница 38: ... Pump Model Cable Size Remora Professional 8 Remora Professional 10 3 x 2 0mm2 Remora Professional 14 3 x 2 5mm2 Remora Professional 19 Remora Professional 25 3 x 4 0mm2 Remora Professional 35 3 x 6 0mm2 The above are for references only Please refer to qualified electricians if in doubt Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales aut...

Страница 39: ... 37 NOTES Automated Environmental Systems Ltd Unit B Anglian Lane Bury St Edmunds Suffolk IP32 6SR 01842 819130 sales automatedenvironmentalsystems co uk ...

Отзывы: