english
vacuum high
(171 - 240 mbar)
vacuum correct
(90 - 170) mbar)
vacuum low
(0 - 89) mbar)
CONTAINER/CLEAN BAG
FILLING LEVEL
This calculates the presumed filling level of the dust
container or CLEAn BAG, using 4 progressive stages.
filling level 25-49 %
filling level 50-74 %
filling level 75-99 %
filling level 100 % - the bag is
completely full and must be
replaced
(see AnOMALy AnD LOCK TABLE)
FILTER CARTRIDGE
SATURATION LEVEL
The filter cartridge saturation level is displayed with 5
progressive stages.
saturation 20 - 39 %
saturation 40 - 59 %
saturation 60 - 79 %
saturation 80 - 99 %
saturation 100 % - the central
control unit stops due to filter
saturation lock.
(see AnOMALy AnD LOCK TABLE)
STARTING ANOMALY/LOCK
Displays an anomaly/lock due to an excessive number of
starts/stops within a 1 minute period.
OPERATING VACUUM RANGE
Indicates the vacuuming power at which the system
is operating. 3 different vacuum levels are shown on
the display
If the system operates at a vacuum level
greater than
240 mbar, the wording will
flash and the central power unit will be
locked after 15 seconds due to excessive
operating vacuum.
(see AnOMALy AnD LOCK TABLE)
MOTOR TEMPERATURE ANOMALY/LOCK
Displays an anomaly/lock due to the motor chamber
temperature exceeding 80°C.
the temperature warning light appears,
which flashes together with the fixed
maintenance warning light that
indicates a central power unit lock due
to motor chamber overheating.
(see AnOMALy AnD LOCK TABLE)
After 5 consecutive starts during a one
minute period, the warning light signals
that the central power unit will be locked
if started again within one minute. (see
AnOMALy AnD LOCK TABLE)
After 6 consecutive starts during a
one minute period, the central power
unit is locked.
(see AnOMALy AnD LOCK TABLE)
After 29 minutes of continuous sys-
tem use, a flashing clock appears that
indicates the maximum use time.
(see AnOMALy AnD LOCK TABLE)
The central power unit is locked due to
continuous system use for 30 minutes.
(see AnOMALy AnD LOCK TABLE)
MAXIMUM USE TIME ANOMALY/LOCK
Displays an anomaly/lock due to continuous use of the
system for 30 minutes.
+
+
+
+
18