english
container eMptYing
This operation is necessary when the full container
warning light lights up on the AVT panel.
1 - Rotate both handles (a) upwards simultaneously. The
dust container will lower.
2 - Empty the dust container in a suitable collection bag
or container and dispose of it correctly (in accordance
with current environmental standards in the country
of use).
3 - Rehook the dust container and close the handles.
orDinarY Maintenance
ON CLASSIC TC CENTRAL POWER UNITS
Careful maintenance prolongs the life-time of the
central power unit and guarantees better performance.
NOTE
Before starting with any maintenance
operation, disconnect the central power
unit from the power supply.
The central power unit must not be operated
without the filter cartridge inserted. Failure
to observe this rule could cause damage
to the motor that is not covered by the
warranty.
filter cartriDge replaceMent
ATTENTION
When carrying out this operation, it is
easy to come into contact with the dust
collected on the cartridge walls.
Before removing the filter cartridge, it is
recommended to wear suitable personal
protective garments.
1 - Open the dust container rotating the handles (a)
This operation is necessary when the saturated filter
cartridge warning light lights up on the AVT panel.
Before starting with any maintenance
operation, disconnect the central power
unit from the power supply.
It is recommended to replace the filter cartridge every
2-3 years.
This period may change depending on the degree of
system use.