6
NOTE
NOTE
NOTE
REQUIRED OUTLETS
Any electrical socket should be checked by an electrician.
120 VAC operation:
a NEMA 5-15R wall outlet is required.
NEMA 5-15R receptacle
120 V
A dedicated 120 VAC single phase circuit and a 15-amp
rated circuit breaker are required.
208/240 VAC operation:
a NEMA 6-20R wall outlet is required.
NEMA 6-20R wall receptacle
240 V
A dedicated 240 VAC split phase circuit or a 208 VAC
two phase circuit and a 20-amp rated circuit breaker are
required.