pag.
25 di 64
Use and Maintenance Manual
M
MCCHH88--1111//EEM
M -- M
MCCHH1133--1166//EETT
Standard
Cap.3 _ Safety regulation
a
Maximum working pressure.
5
a
a
Cartridge change info label.
Filter with active carbon molecular sieve cartridge.
To change the filter refer to “7.11.1 Filter replacement
frequency calculation table” and “7.11.2 Changing
the active carbon filters”.
FILTER WITH CARTRIDGE
TO BE REPLACED AT REGULAR
INTERVALS – SEE MANUAL
6
a
a
Special oil info plate.
Indicates that only special oils must be used for high
pressure compressors.
To choose the right oil see section “7.6.1 Oil table”.
b
Oil level check info plate.
Check lubricating oil level every 5 working hours and
change it every 50 working hours.
For information on how to check see “7.6.2
Checking the oil level”.
For information on how to change the oil see “7.6.3
Changing the lubricating oil”.
USE SPECIAL OIL
FOR HIGH PRESSURE
COMPRESSORS
WARNING
CHECK OIL LEVEL
EVERY 5 HOURS AND
CHANGE OIL EVERY
50 WORKING HOURS
7
a
b
a
Condensate separator info label.
Indicates that the condensate must be emptied via
the drain taps every 10-15 minutes.
WARNING
CONDENSATE SEPARATOR
EMPTY EVERY 10-15 MINUTES
8
a
a
Condensate discharge info plate.
Indicates position of condensate discharge tap.
To discharge the condensate see “7.9 Condensate
discharge”.
CONDENSATE DISCHARGE
9
a
IMPORTANT
Except for version with automatic condensate discharge.