Installation and Configuration
Ensemble CP
2.4.1. Typical ESTOP Interface
The user can connect an external emergency stop relay circuit to the Ensemble CP’s motor power supply
input. This will remove power to the motor while maintaining control power, as shown in the
Figure 2-33
.
The external relay must be sized based on the number of the Ensemble CPs connected and the peak current
rating of each drive.
CP #1
CR1
AC1
AC2
115-230 VAC
50/60 Hz
Input
SAFETY
GROUND
CR1
ESTOP
Control Relay
Coil
AC2
T
B1
0
1
EST
O
P
T
B1
0
1
EST
O
P
CP #2
AC1
AC2
+24V
User-Supplied
+24VDC
Supply
COM
1
2
1
2
AC2
T
B1
0
2
Mo
to
r
Su
p
p
ly
AC1
AC2
T
B1
0
2
Mo
to
r
Su
p
p
ly
AC1
T
B1
0
6
C
o
n
tr
o
l S
u
p
p
ly
1. Motor power may be removed during an Emergency Stop (ESTOP) condition while control and encoder power is maintained.
2. For the ESTOP input to be active, set the appropriate FaultMask axis parameters (the FaultMask axis parameters set the
action to be taken when an ESTOP condition occurs).
3. Branch protection (fuses or circuit breaker) required
4. AC line filters are required for CE compliance.
FOLLOW ALL APPLICABLE WIRING AND SAFETY CODES
HAZARDOUS VOLTAGES PRESENT
4
3
2
2
1
1
1
AC1
AC2
115-230 VAC
50/60 Hz
Input
SAFETY
GROUND
4
4
AC1
T
B1
0
6
C
o
n
tr
o
l S
u
p
p
ly
4
Figure 2-33:
Typical Emergency Stop Circuit
Table 2-24:
Typical ESTOP Relay Ratings
Axes
AC1
AC3
Aerotech P/N
Third Party P/N
1
32
16
ECW1018
Sprecher & Schuh CA7-16C-xx-xxx
2 to 5
85
43
ECW1019
Sprecher & Schuh CA7-43C-xx-xxx