Maintenance
Ensemble CP
Table 5-2:
Control Board Jumper Configuration
Jumper
Setting
Description
JP3
1-2
(1)
Watchdog enabled
2-3
Watchdog disabled
JP4
1-2
(1)
No shunt option present
2-3
Shunt option present
JP6
1-2
(1)
24 V operation (High Speed Input 4)
2-3
5 V operation (High Speed Input 4)
JP7
1-2
(1)
24 V operation (High Speed Input 5)
2-3
5 V operation (High Speed Input 5)
1. Default
Table 5-3:
Control Board Fuse Information
Fuse
Description
Size
Aerotech P/N
Manufacturer's P/N
F1
-S Option Shunt Fuse
1 A S.B. (5 mm)
EIF01052
Littelfuse 215001.P
-EXTSHUNT Option Shunt Fuse
2.5 A S.B.
EIF01053
Littelfuse 21502.5P
F3
Control Power Fuse
2 A S.B.
EIF01029
Littelfuse 3721200041
F4
Ensemble CP 10; VAC Input at TB102-1
5 A S.B. (5 mm)
EIF01023
Littelfuse 215005.P
Ensemble CP 20; VAC Input at TB102-1
10 A S.B. (5
mm)
EIF01006
Littelfuse 218010
Ensemble CP 30; VAC Input at TB102-1
10 A S.B. (5
mm)
EIF01006
Littelfuse 218010
Table 5-4:
LED Description
LED
Description
ENB/FLT
Turns green to indicate that the axis is enabled. Turns red to indicate a fault condition. The
ENB/FLT LED will flash between RED and GREEN if the drive is enabled and in a fault
condition.
MARKER
Turns green to indicate that the marker input is high.
PWR*
Turns green when power is applied.
POS
Turns green to indicate that the axis is in position.
* If the power light flashes continuously and the unit does not operate, there is too much current draw from the 5V power supply or
the control supply voltage level is low.