4.4. Troubleshooting
Table 4-1:
Troubleshooting
Symptom
Possible Cause and Solution
Stage will not move
l
Shipping restraints still installed. Remove the red anodized shipping
brackets.
l
Brake not released (if equipped with brake; refer to stage documentation).
l
In Limit condition. Check limits (refer to
Chapter 3: Electrical Installation
)
and refer to the Controller documentation for polarity and compatibility
requirements (Example: voltage requirements).
l
Controller trap or fault (refer to the Controller documentation).
Stage moves
uncontrollably
l
Encoder (sine and cosine) signal connections (refer to
and Controller documentation).
l
Motor Connections (refer to
Chapter 3: Electrical Installation
and the
Controller documentation).
Stage oscillates or
squeals
l
Gains misadjusted (refer to the Controller documentation).
l
Encoder signals (refer to the Controller documentation).
APR100DR
Hardware Manual
48
www.aerotech.com
Содержание APR100DR Series
Страница 1: ...Revision 2 00 APR100DR High Precision Mechanical Bearing Rotary Stage HARDWARE MANUAL...
Страница 21: ...Figure 2 2 APR100DR Stage Mounting Holes Hardware Manual APR100DR www aerotech com 21...
Страница 23: ...Figure 2 3 Cantilevered Load Capabilities Hardware Manual APR100DR www aerotech com 23...
Страница 24: ...This page intentionally left blank APR100DR Hardware Manual 24 www aerotech com...
Страница 32: ...Figure 3 3 APR100DR Motor and Feedback Wiring E4 APR100DR Hardware Manual 32 www aerotech com...
Страница 33: ...Figure 3 4 APR100DR Motor and Feedback Wiring E5 E6 Hardware Manual APR100DR www aerotech com 33...
Страница 40: ...This page intentionally left blank APR100DR Hardware Manual 40 www aerotech com...
Страница 44: ...Figure 4 1 APR100DR Limit Flag Adjustment APR100DR Hardware Manual 44 www aerotech com...
Страница 52: ...This page intentionally left blank APR100DR Hardware Manual 52 www aerotech com...