4.5 Taxiing
1. Throttle
– IDLE.
2. Taxiway
– CHECK CLEAR.
3. Coolant and oil temperature
– CHECK.
4. Parking brake
– OFF.
5. Throttle
– SET REQUIRED TAXI SPEED.
6. Yoke/Stick
– elevator NEUTRAL, ailerons AGAINST crosswind.
7. Brakes
– use as required, set throttle to IDLE when stopping.
8. To stop immediately
– IGNITION OFF and ENGAGE BRAKES.
4.6 Before takeoff
1. Hold position
– LINE UP AND WAIT.
2. Brakes
– ENGAGE.
3. Coolant temperature
– CHECK minimum 140°F (60°C).
4. Oil temperature
– CHECK minimum 120°F (50°C).
5. Fuel level
).
6. Fuel valves
).
7. Flaps
– EXTEND position 1.
4.7 Normal takeoff
1. Rudder pedals
– NEUTRAL.
2. Brakes
– RELEASE.
3. Throttle
– gradually FULL POWER.
4. Yoke/Stick
– elevator NEUTRAL, ailerons AGAINST CROSSWIND.
5. Rudder pedals
– maintain takeoff direction.
6. Yoke/Stick
– PULL gently to lift the nose wheel at 40 km/h.
7. After take-off accelerate to at least 80 km/h (50 mph, 43 kts) and start to climb.
4.8 Short/soft field takeoff
1. Flaps
– EXTEND FULLY.
2. Hold position
– OCCUPY.
3. Takeoff distance
– CHECK if sufficient.
4. Rudder pedals
– NEUTRAL.
5. Throttle
– gradually FULL POWER.
6. Brakes
– RELEASE.
7. Yoke/Stick
– elevator NEUTRAL, ailerons AGAINST CROSSWIND.
8. Rudder pedals
– maintain takeoff direction.
9. Liftoff
– at 65 km/h (35 kts).
Содержание A32-iS-129-POH
Страница 26: ...AEROPRAKT 32 Pilot Operating Handbook A32 iS 129 POH 26 No Equipment description and Part No Weight kg CG arm m...
Страница 36: ...AEROPRAKT 32 Pilot Operating Handbook A32 iS 129 POH 36 Fig 10 Brake control system...
Страница 41: ...AEROPRAKT 32 Pilot Operating Handbook A32 iS 129 POH 41 Fig 13 Wiring diagram of A 32 electrical system main...
Страница 47: ...AEROPRAKT 32 Pilot Operating Handbook A32 iS 129 POH 47 Fig 19 Recovery system...